REV. 8-24-18 Page 3
PAVER-CP-TMSI
STEP 1:
Determine the best location to install the paver
kit control panel per your installation.
STEP 2:
Remove one block from your fi re pit enclosure
then measure the width between the opening.
Depending on the block width the control panel can be
adjusted to fi t various openings.
NOTE:
When
measuring it is recommended but not required to
recess the control panel to protect the valve
components from weather.
STEP 3:
After you have determined the location and
measured the width to install the Paver Kit control panel
mark the inside of the control panel as shown in Fig. 4.
STEP: 4
Drill the two holes with a 3/16” concrete drill
bit and secure the paver kit control panel with concrete
screws.
Use the linel to support the paver above control panel.
The lintel simply lays on top of the paver as shown in
Fig. 4.
NOTE:
This section provide a general installation of
the Paver Kit Control Panel. See Table of Contents for
specifi c instruction for your application. Follow the
directions from your paver block fi re pit kit to build the
actual fi re pit. Depending on your fi re pit pan (fl at disc
or pan) ensure the Paver Kit control panel is installed
underneath the pan or disc.
Be sure the paver patio block kit fi ts the opening of the
fi re pit pan or disc before beginning your installation.
Fig. 4
Securing the control panel into the paver block. Lintel
is shown in the gray shading.
Fig. 5
Control panel installed, ready for valve bracket.
Paver Block
Paver Block
Place control panel into position, mark the
two holes, remove the control panel and
drill holes with 3/16” concrete drill bit.
Paver Block
Paver Block
LINTEL
GENERAL INSTRUCTIONS
Remove the TMSI valve and bracket assembly from the
plastic bag.
STEP 1:
Prepare the fi re pit gas valve by installing a ⅜” close
nipple and ½” OD Flare x ⅜” brass fi tting that comes with the
PAVER-CP-TMSI kit into the gas inlet. Use gas rated Tefl on
tape or compound on the male threads. Ensure the fi ttings
are tight to prevent any gas leaks.
CAUTION:
Do not use any Tefl on tape or compound on the
fl ared ends of the fi ttings.
TMSI VALVE INSTALLATON
(U1-8C-S)
½" OD Flare x
3⁄8" MIP
Gas Inlet
Piezo Ignitor
Fig. 6 Shows valve assembly removed from shipping bag.