Firegear PAVER-CP-MT Installation And Operating Instructions Manual Download Page 8

REV. 10-18-19  Page 8

PAVER-CP-MT/ PAVER-CP-MSI

MT-MSI LIGHTING INSTRUCTIONS

 

Firegear Outdoors warrants the Paver Kit for 12 months from date of purchase or installation to original purchaser to be 

free from defects in materials and workmanship. Damage to the Paver Kit caused by accident, misuse, abuse, or 

installation error, whether performed by a contractor, service company, or owner, is not covered by this warranty. 

Firegear Outdoors will not be responsible for labor charges and/or damage incurred in installation, repair, replacement, or 

for incidental or consequential damage. Some states, provinces, and nations do not allow exclusion or limitations of 

incidental or consequential damages, so the above limitations or exclusions may not apply. This warranty gives you 
specific legal rights. You may also have other rights that vary by state, province, or nation.

LIMITED WARRANTY

Fig. 21.

 Piezo button and key valve.

TURNING OFF FIRE PIT

1.  Insert key and turn clockwise to OFF. Fire pit will turn OFF.

2.  After cooling off install cover (if applicable).

READ ALL LIGHTING INSTRUCTIONS BEFORE ATTEMPTING TO LIGHT FIRE PIT

CAUTION

:   

ENSURE YOU HAVE LEAK TESTED THE FIRE PIT BEFORE OPERATING.

WARNING: Do not stand over fire pit during ignition or operation due to high surface temperatures. 

LIGHTING INSTRUCTIONS

TURNING ON FIRE PIT

1.  Depress and hold the red Piezo ignitor button and ensure sparking is occurring at the probes inside ignition hood.

2.  Insert key into gas valve and turn counter clockwise to the ON position.

3.  After the fire pit lights release the Piezo button. If fire pit does not light within 30 seconds, turn key clockwise to turn 

OFF and wait 5 minutes before trying again. Turn gas supply OFF to check probe spacing and Piezo battery if fire pit 

does not light.

4.  Repeat steps 1-4.

ON

OFF

AT ON POSITION 

SLIGHT PUSH TO 

TURN OFF

FULL PUSH TO 

LIGHT

Red Piezo Button

Control Knob

ON      OFF

Key Valve

Summary of Contents for PAVER-CP-MT

Page 1: ...llation and Operating Instructions CALIFORNIA PROPOSITION 65 WARNING This product is designed to operate with one of the following fuel sources Liquid Propane or Natural Gas The fuel used to operate this product and the products of combustion of such fuel can expose you to chemicals including Benzene which is known to the State of California to cause cancer birth defects and other reproductive har...

Page 2: ...in the Extension Bracket are spaced every 10 Max 8 00 Min 3 Fig 3 Paver Kit Control Panel Dimensions Fig 1 Paver kit with fire pit pan Fig 2 Paver kit with fire pit flat disc with flex frame TOOLS NEEDED 1 Drill driver Gas Rated Teflon Tape or Compound 5 16 Hex head driver 1 3 16 Concrete Drill Bit 2 Adjustable Wrenches Assorted Open end Wrenches PRECAUTION If you are installing the MSI Manual Spa...

Page 3: ...re the Paver Control Panel is installed underneath the pan or disc Be sure the paver patio block kit fits the opening of the fire pit pan or disc before beginning your installation Fig 4 Top view of control panel securing into the paver block Fig 5 Front view of control panel installed ready for valve bracket Paver Block Paver Block Place control panel into position mark the two holes remove the c...

Page 4: ...hread cutting screws See Fig 8 STEP 4 Install the flex connector from the burner to either side of the gas valve and connect gas supply to the other side of the gas valve Conduct a trial burn test by tempo rarily connecting the fire pit pan and burner and check for any gas leaks before completing the installation See fire pit manual for proper connections See page 5 for lighting instructions STEP ...

Page 5: ...AND SAFETY INFORMATION ABOVE BEFORE ATTEMPTING TO LIGHT FIRE PIT CAUTION ENSURE YOU HAVE LEAK TESTED THE FIRE PIT BEFORE OPERATING TURNING ON FIRE PIT 1 Insert key into shut off valve and secure into square end see Figs 9 11 2 Light a long match or butane lighter and hold it near the burner 3 Turn the key slowly counter clockwise in gas valve until it stops to allow gas to flow and simultaneously ...

Page 6: ...gnition assembly to the pan using the four previously removed screws Note The metal tab aligns the burner leg underneath the spur hood as shown in Fig 14 Tabs Center Burning Spur Leg Screws Install From Bottom Up Top of Pan Fig 14 Installing screws from bottom of pan Step 5 Using a power screwdriver install the ignition hood over top of the MSI assembly plate See Fig 15 Align the five holes from t...

Page 7: ...shing and holding the red button to ensure the 2 probe ignitor is sparking inside the ignition box in the burner pan The spark should be located directly over top of the burner port hole for proper ignition of the gas as previously discussed Spacing between the probes should be approximately 1 8 for proper spark See Fig 14 on page 4 if necessary Step 10 Install the ignition hood screen mesh and en...

Page 8: ... or nation LIMITED WARRANTY Fig 21 Piezo button and key valve TURNING OFF FIRE PIT 1 Insert key and turn clockwise to OFF Fire pit will turn OFF 2 After cooling off install cover if applicable READ ALL LIGHTING INSTRUCTIONS BEFORE ATTEMPTING TO LIGHT FIRE PIT CAUTION ENSURE YOU HAVE LEAK TESTED THE FIRE PIT BEFORE OPERATING WARNING Do not stand over fire pit during ignition or operation due to hig...

Page 9: ...x 6 1 Ignition Hood Screen ST3 100 1027 x 7 1 Ignition Hood SPURHOOD x 8 1 Ignition Module 3042 RB x 9 1 23 Piezo Ignition Wire PIEZO23WH x 10 1 48 Piezo Ignition Wire PIEZO48WH x 11 1 AAA Battery BATTAAA x 12 1 Male Spade Terminal GROUNDTAB x x 13 1 Black Nylon Plug BPFE 15 MM x x 14 1 Match Throw MT Face Plate MT FACEPLATE SS x x 15 2 Flare x MIP Brass Elbow 49 88 x x 16 2 x 1 Concrete Screws no...