10
NFOD42 Gas Fireplace
INSTALLATION
)5$0,1*',0(16,216
A
B
C
D
Metal Stud
on edge
G
F
Note:
All other framing may
be of wood construction.
E
)UDPLQJ
'LPHQVLRQV
'HVFULSWLRQ
1)2'
A
Header Height
32-11/16” (30mm)
B
Side Stud Width
42 - 3/16" (1072mm)
C
Minimum framing depth
20" (508mm)
D
Minimum Height to Combustibles
52 - 1/2" (1334mm)
E
Minimum framing width
60" (1524mm)
F
Corner Wall Depth
40 - 7/16" (1027mm)
G
Corner Facing Wall Width
54 - 3/16" (1376mm)
H
Gas Connection Opening Height
2" (51mm)
I
Gas Connection Height
3-7/8 " (98mm)
J
Gas Connection Inset
3/4" (73mm)
K
Gas Connection Opening Width
3-7/8 " (98mm)
Framing depth measurement is noted with the nailing strips set as far forward on the firebox as possible.
The nailing strips can be adjusted back up to 1” to allow for varying thicknesses in non-combustible
material & wall finishes.
I
J
J
K
Important Note:
Two (2) ventilation grills are highly recommended for all enclosures.
This is to alleviate moisture and allow for air to circulate. Minimum recommended size: 20" sq (508 mm