background image

REV. A      Page 11

Drop in Pan - AWS Fire Pits

FINAL PREPARATIONS

WIRING DIAGRAMS FOR A SINGLE INSTALL

Gas 

Supply

Non-Combustible Enclosure

 Burner

Key Valve

LEARN

Weather 

Proof 

Box

Weather 

Proof 

Box

Red

Red

Red

Red(+)

Black (-)

Red

Black

Red Sleeve

FG-1420-AOD 

Receiver

GOE-30VDC 

Power Supply

Heat 

Shield

120VAC 

Power GFI 

Outlet

Orifice

Flat Pan

Pilot

Fig.9  

Shows typical installation of fire pit using AWS system with a switch.

Fig. 10  

Wire diagram of AWS system with optional 1420-A remote control receiver.

Gas 

Supply

Non-Combustible Enclosure

 Burner

Weather 

Proof 

Box

Red(+)

GOE-30VDC 

Power Supply

Heat 

Shield

120VAC 

Power GFI 

Outlet

Orifice

Flat Pan

Pilot

Switch

Switch Side View

Close-Up

(To Valve Box)

(To 

GOE-30VDC)

(-) (+)

(+)

(+)

Black (-)

Summary of Contents for LOF-2408FTAWS-N

Page 1: ... LOF 8416FHAWS N P 81 x 10 Burner 225 000 Btu s LOF 9616FHAWS N P 93 x 10 Burner 250 000 Btu s MODELS H Burner Models T Burner Models DO NOT DISCARD THIS MANUAL HAS IMPORTANT OPERATING AND MAINTENANCE INSTRUCTIONS LEAVE WITH THE HOMEOWNER MODEL SERIAL Models NG LP T Burner Input Rating LOF 2408FTAWS N P 21 Burner 50 000 Btu s LOF 3008FTAWS N P 27 Burner 50 000 Btu s LOF 3608FTAWS N P 33 Burner 75 ...

Page 2: ...partment DANGER WARNING Do not store or us gasoline or other flammable vapors and liquids in the vicinity of this or other appliances Any LP cylinder not connected for use shall not be stored in the vicinity of this or other appliances WARNING Do not leave unattended during use Do not use for cooking Follow all gas leak procedures in this manual prior to operation WARNING Improper installation adj...

Page 3: ...s the media has the potential to crack or pop outside the fireplace WE HIGHLY RECOMMEND COVERING ALL FIRE FEATURES WHEN NOT IN USE The use of a cover can lessen the impact of thermal spalling however heavy rains high humidity and the presence of moisture may still cause the media to pop ALWAYS USE CAUTION WHEN USING THE FIRE FEATURE Extra caution should be taken when lighting a fireplace when heav...

Page 4: ... x 381mm 8 203mm 36 914mm 120 3048mm 18 457mm LOF 9616FHAWS N LOF 9616FHAWS P 96 x 16 2438 x 406mm 93 x 10 2362 x 254mm 94 x 14 2387 x 381mm 8 203mm 36 914mm 120 3048mm 18 457mm A A B B Fig 1 H style burner pan specifications SPECIFICATIONS Model N NG P LP NG Orifice Btu Ratings LP Orifice LOF 2414FHAWS N LOF 2414FHAWS P OAS NG29 75 000 21 98kW OAS LP41 LOF 3014FHAWS N LOF 3014FHAWS P OAS NG22 100...

Page 5: ...AWS N LOF 9608FTAWS P 96 x 8 2438 x 203mm 93 2362mm 94 x 7 2387 x 152mm 8 203mm 36 914mm 120 3048mm 18 457mm SPECIFICATIONS Model N NG P LP NG Orifice Btu Ratings LP Orifice LOF 2408FTAWS N LOF 2408FTAWS P OAS NG34 50 000 14 65kW OAS LP47 LOF 3008FTAWS N LOF 3008FTAWS P OAS NG34 50 000 14 65kW OAS LP47 LOF 3608LTAWS N LOF 3608LTAWS P OAS NG29 75 000 21 98kW OAS LP41 LOF 4808LTAWS N LOF 4808LTAWS P...

Page 6: ...around the pipe with weather sealant Consult a plumber for proper installation to ensure you are providing adequate gas supply for your application 4 The primary gas shut off not supplied will require a male flared fitting to enable connection of the stainless steel flex gas line not supplied with the fire feature see Fig 5 page 9 5 Do not place an LP tank inside any fire pit enclosure Locate all ...

Page 7: ...ired for the amount of BTU s for a new gas line installations If you are using an existing gas line you must take into consideration the existing gas line capacities to ensure you will have proper pressure This chart is for reference only we recommend you consult with a Licensed Plumber Gas Fitter or NFPA54 National Fuel Gas Code current edition for more details Length of Pipe in Feet 1 2 3 4 1 1 ...

Page 8: ...on holes at the base of the orifice to provide a cleaner flame See Fig 5 ELECTRICAL INFORMATION Wire Gauge Is the wire gauge correct Wiring must be 12AWG or greater solid or stranded for all installations Note It is recommended to fill the wire nuts with either dielectric grease or silicone prior to installing the wire nut This will ensure a waterproof connection Why GFI circuit A GFI is a type of...

Page 9: ...l Line Gas Line ON OFF or or Main Burner Flat Pan Pilot Burner Min 12 gauge Flex Frame shown in detail enables the ability to remove the pan disc to service valve system Flex Frame Min Max Distance Pilot Run 6 to 22 Optional ON OFF Controls Note Actual power supply must be 10 feet or more from the pool or spa DETAIL Pool Control Pool Certified Applications Fire Feature within 5 feet of pool or spa...

Page 10: ...ns provided with the remote control to learn program the transmitter to the receiver Use dielectric grease on all wire nut connections and connectors to prevent moisture issues from the outdoor environment Fig 8 Shows carton contents Note H burner was illustrated for this drawing The AWS system is polarity sensitive There is a red sleeve attached to the positive side of the adapter When wiring the...

Page 11: ...ver GOE 30VDC Power Supply Heat Shield 120VAC Power GFI Outlet Orifice Flat Pan Pilot Fig 9 Shows typical installation of fire pit using AWS system with a switch Fig 10 Wire diagram of AWS system with optional 1420 A remote control receiver Gas Supply Non Combustible Enclosure Burner Weather Proof Box Red GOE 30VDC Power Supply Heat Shield 120VAC Power GFI Outlet Orifice Flat Pan Pilot Switch Swit...

Page 12: ... burner port holes Do NOT cover the top of the screen hood with any rock or glass It must be free an any debris to operate properly Media Required Per H Burner Models Lava Rock Only Glass Only Lava Stones Only LOF 2412FHAWS N LOF 2412FHAWS P 10lbs 15lbs 10lbs LOF 3012FHAWS N LOF 3012FHAWS P 15lbs 20lbs 15lbs LOF 3614FHAWS N LOF 3614FHAWS P 20lbs 25lbs 20lbs LOF 4814FHAWS N LOF 4814FHAWS P 30lbs 35...

Page 13: ...evere burns if contacted 2 Do not burn any solid fuels in this appliance READ ALL LIGHTING INSTRUCTIONS BEFORE ATTEMPTING TO LIGHT FIRE PIT CAUTION ENSURE YOU HAVE LEAK TESTED THE FIRE PIT BEFORE OPERATING AND THE TRANSMITTER AND RECEIVER HAVE BEEN LEARNED PROGRAMED TOGETHER FOR WIRELESS OPERATION WARNING Do not stand over fire pit during ignition or operation due to high surface temperatures LIGH...

Page 14: ...REV A Page 14 Drop in Pan AWS Fire Pits AWS REPLACEMENT PARTS 1 2 6 7 5 Drawings not to scale 4 3 8 14 9 11 10 12 13 15 OUT GOE 30DCV Junction Box Weatherproof Cover Lid 7A ...

Page 15: ...1 78057 3 36 x 8 LT Flat Burner Pan Used with 33 T burner 1 78049 3 48 x 8 LT Flat Burner Pan Used with 45 T burner 1 78050 3 60 x 8 LT Flat Burner Pan Used with 57 T burner 1 78051 3 72 x 8 LT Flat Burner Pan Used with 69 T burner 1 78052 3 84 x 8 LT Flat Burner Pan Used with 81 T burner 1 78053 3 96 x 8 LT Flat Burner Pan Used with 93 T burner 1 78062 4 21 T Burner Only used with 24 x 6 T burner...

Page 16: ...rainy weather conditions when not in use Heavy rains downpours could affect the fire pit operation if not covered if this occurs ensure you allow the fire pit time to dry out before attempting to operate NOTE If a combustible type cover is used over the fire pit when not in use be sure to remove it before operation to prevent a severe safety hazard 5 Carbon soot may build up on the surface of logs...

Page 17: ...6 LOF 8406FTAWS N LOF 6016FHAWS N FG AWS PBO P 200 000 58 61kW OAS LP22 LOF 9606FTAWS N LOF 7216FHAWS N FG AWS PBO P 225 000 65 94kW OAS LP19 LOF 8416FHAWS N FG AWS PBO P 250 000 73 26kW OAS LP12 LOF 9616FHAWS N Table 6 LP Conversion Chart Gas Supply ble Enclosure Burner Key Valve LEARN Weather Proof Box ther of x Red Red Red Red Black Red Red Sleeve FG 1420 AOD Receiver Heat Shield Orifice Flat P...

Page 18: ...cted 120VAC power directly to the gas valve the controller inside the valve box will be damaged It this happens a burned electrical smell might be present Connector Not Plugged In Correctly Check the 2 Pin connector from pilot to the gas valve Ensure it is plugged into place with the locking latch Pins Not Secure Check the pins inside the 2 pin connector ensure they are not loose If loose push the...

Page 19: ...ermopile from the pilot assembly and slide it out If it will not slide out because is it too tight then it will need to be replaced Debris Debris can get trapped inside the screen of the gas valve Over time rust and other debris can restrict the gas flow on the Outlet screen of the valve that can partially or sometimes even stop the flow Inspect the screen remove it and clean it then replace it De...

Page 20: ...t Remove some of the fire glass media from the burner to see if this fixes the problem Gas Leak Natural Gas is lighter than air therefore when released into the atmosphere it rises If you have a Natural Gas fire feature and there is a gas leak the Natural Gas will rise to the top of the feature Once it encounters the flame a flare up will occur Propane is heavier than air so if there is a gas leak...

Page 21: ...eld to fit your application FLEXFRAME Universal brackets to support fire pit when using paver blocks or other non combustible enclosures Model FLEXFRAME SS 2 piece Model FLEXFRAME SS3 3 piece Paver Control Panels PAVER CO AWS AWS systems Vent Kits Provide 18 sq in of ventilation per side of enclosure Model VENT KIT 6X12SS Model PAVER VENT 4 LNTS Model PAVER VENT 6 LNTS Emergency Stop Emergency shu...

Page 22: ... WARRANTY REFRACTORY GAS LOG SETS FIVE 5 YEAR WARRANTY READY TO FINISH ANF FIRE PIT ENCLOSURES FIVE 5 YEAR WARRANTY SKYTECH MANUACFTURED OPTIONAL CONTROLS OUTDOOR FIREPLACE KALEA BAY LIFETIME WARRANTY CONSTRUCTION AND MANUFACTURER DEFECTS LIFETIME WARRANTY STAINLESS STEEL COMPONENTS FIVE 5 YEAR WARRANTY GAS VALVE PILOT ASSEMBLY POWER SUPPLY CONTROLS FIVE 5 YEAR WARRANTY SKYTECH MANUACFTURED OPTION...

Page 23: ...E KALEA BAY LIFETIME WARRANTY CONSTRUCTION AND MANUFACTURER DEFECTS LIFETIME WARRANTY STAINLESS STEEL COMPONENTS TWO 2 YEAR WARRANTY GAS VALVE PILOT ASSEMBLY POWER SUPPLY CONTROLS TWO 2 YEAR WARRANTY SKYTECH MANUACFTURED OPTIONAL CONTROLS SANCTUARY SERIES GFRC FIRE FEATURES THREE 3 YEAR WARRANTY GFRC STRUCTURE REFER TO THE APPROPRIATE BURNER SYSTEM FOR WARRANTY WARRANTY COVERS MANUFACTURING DEFECT...

Page 24: ...r the defect on warranty parts to and from the factory will be the responsibility of the owner We will not be responsible for labor charges and or damage incurred in installation repair and replacement Firegear is not responsible for Issues related to gas or electrical installation The Limited Warranty is voided if not assembled installed and operated as intended This Limited Warranty does not cov...

Page 25: ...r the defect on warranty parts to and from the factory will be the responsibility of the owner We will not be responsible for labor charges and or damage incurred in installation repair and replacement Firegear is not responsible for Issues related to gas or electrical installation The Limited Warranty is voided if not assembled installed and operated as intended This Limited Warranty does not cov...

Page 26: ...ental or consequential damages so this limitation or exclusion may not apply to you We do not authorize any person or company to assume for it any other obligation or liability in connection with the sale installation use removal return or replacement of its equipment and or such representation are binding Firegear Outdoors 17322 Gothard Street Huntington Beach CA 92647 www firegearoutdoors com Ph...

Page 27: ...REV A Page 27 Drop in Pan AWS Fire Pits NOTES ...

Page 28: ..._ 2 Serial Number ___________________________ 3 How long is the gas line run Nat Gas ____ LP Gas ____ 4 What size is gas line _____ 5 Inlet Gas Pressure _____WC Manifold Gas Pressure _____ WC 6 What type of media are you using __________________ 7 Review the troubleshooting section in the installation manual 8 What are the symptoms Please be prepared to explain 9 Be prepared to send photos to us w...

Reviews: