WARNING: 

Proper clearances from combustible materials must be maintained from all sides, top and bottom of this 

appliance. Use the specifications listed on page 4 for proper clearance to combustibles. 

PREPARING A NON-COMBUSTIBLE STRUCTURE

The fire pit can be installed on a flat, stable surface, away from any combustible materials. Install Fire pit on any level, 

outdoor non-combustible, flat stable surface or a combustible floor according to the clearances specified in this manu-

al. 

NOTE

: Do not place fire pit directly on grass, dirt, or rocks this may prevent proper ventilation (Fig.1, pg. 4).  

Ensure 

proper water drainage is also incorporated into the fire  pit enclosure.

HARD PIPING TO FIRE PIT WITHOUT GAS PROXIMITY

NOTE:

  We recommend using ¾” black iron pipe; however please refer to the NFPA54 (National Fuel Gas Code) for 

proper pipe sizing when exceeding 20-feet in length for fire  pits rated above 100,000 Btu’s.

1. Turn 

OFF

 gas supply system. 

NOTE

: All gas connections (except for brass to brass) require the following. Clean pipe 

threads using either a wire brush or steel wool. Apply pipe sealant to the fittings before making any connection. 

BE CAREFUL!

 Ensure all gas connections are snug, but do not over tighten!

2. Extend the gas supply system using minimum of ¾” black iron pipe or an approved flexible gas line from existing 

house supply.  This can be accomplished by teeing off or tapping into a gas line connection. Install necessary pipe for the       

distance required and then install a manual shut-off valve at the exterior house wall. If pipe is to pass through a foundation 

or house wall, make sure to re-seal the area around the pipe with weather sealant.

3. The primary gas shut-off (not supplied) will require a ½” male flared fitting to enable connection of the stainless steel 

flex gas line supplied with the fire pit (see Fig. 7 page 9).

IMPORTANT

Installation of Natural or LP gas should be done by a qualified 

installer, service agency or gas supplier. This appliance must 

be isolated from the gas supply piping system by closing its 

manual shutoff valve during any pressure testing of the gas 

supply piping system at test pressures equal to or less than 

½” psig (3.5kPa)

VENTILATION FOR NON-COMBUSTIBLE ENCLOSURE

Fire pits are subjected to many outdoor elements such as rain, 

snow, wind, heat or cold.  

A minimum of 18 square inches 

(per side) of cross ventilation is required to keep the 

components in good working order. 

 Use Fig. 5 as guide to 

assist to incorporate proper ventilation.  

Fire Pit 

Enclousure

(2) 6”x12”

 

Fire Pit Pan/Disc

Examples of Cross Ventilation

2- Firegear 6 x12 vents 

(Model # VENT-KIT-6X12)

Cross Flow  Ventilation 

(Min. 18 Sq. In. Per Side)

Fig. 5

 Cross Ventilation Example

Summary of Contents for FPB-25SFPSBR21 MT-N

Page 1: ...of cross ventilation Failure to provide proper ventilation will void the warranty Natural Gas Models Propane Gas Models Description FPB 26DPSBR21MT N FPB 26DPSBR21MT P 19 Round Pan with 21 Pro Brass...

Page 2: ...ff gas to the appliance 2 Extinguish any open flame 3 If odor continues keep away from the appliance and immediately call your gas supplier or fire department DANGER WARNING Do not store or use gasoli...

Page 3: ...s happens the media has the potential to crack or pop outside the fireplace WE HIGHLY RECOMMEND COVERING ALL FIRE FEATURES WHEN NOT IN USE The use of a cover can lessen the impact of thermal spalling...

Page 4: ...s A Disc Depth B Disc Diameter C Burner Size Min Opening D Ground Level E Side Wall F Combustible Ceiling G Combustible Floor FPB 26DPSBR21MT N FPB 26DPSBR21MT P 1 16 26 Rd 21 24 8 36 120 18 FPB 29DPS...

Page 5: ...s required for the amount of BTU s for a new gas line installations If you are using an existing gas line you must take into consideration the existing gas line capacities to ensure you will have prop...

Page 6: ...ontents The box includes a flex gas line key valve flange key and flared fitting with nipple Inspect for any damage or missing parts See Fig 4 Install the flared fitting and nipple into the bottom of...

Page 7: ...ten 2 Extend the gas supply system using minimum of black iron pipe or an approved flexible gas line from existing house supply This can be accomplished by teeing off or tapping into a gas line connec...

Page 8: ...outdoor use only Not approved for any indoor use 9 This fire pit is designed to have lava rock completely covering the spur burner so that the burner is not visible Do not cover more than 1 above the...

Page 9: ...s Supply Key Valve Side View Det a i l Fig 7 Typical installation NOTE Key valve and flexible gas lines are supplied Gas shut off is not supplied Note A 1 x 2 black iron or galvanized coupler nipple n...

Page 10: ...connection before each use of the appliance 6 Temporary storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply Natural or L P gas line WARNING 1 This ap...

Page 11: ...REV A Page 11 FPB Pro Spur Burners Fire Pits with MT System MT REPLACEMENT PARTS 1 2 6 3 8 4 9 10 Drawings not to scale O N O F F 7 5...

Page 12: ...ur fire pit to protect it from humid rainy weather conditions when not in use Heavy rains downpours could affect the fire pit operation if not covered if this occurs ensure you allow the fire pit time...

Page 13: ...Web Site www firegearoutdoors com 800 966 8126 See Firegear Outdoors catalog for other accessories E STOP Gas shut off valve with mechanical timer and emergency shut off Models ESTOP1 0H 1 hour timer...

Page 14: ...D S Fitting Fire Pit Disc Inlet Gas Supply Expanded View of Match Throw MT Fire Pits T200 9898 46 Flex Connector Note Use joint compound or Teflon tape resistant to all gasses on all male NPT threads...

Page 15: ...VE 5 YEAR WARRANTY REFRACTORY GAS LOG SETS FIVE 5 YEAR WARRANTY READY TO FINISH ANF FIRE PIT ENCLOSURES FIVE 5 YEAR WARRANTY SKYTECH MANUACFTURED OPTIONAL CONTROLS OUTDOOR FIREPLACE KALEA BAY LIFETIME...

Page 16: ...FIREPLACE KALEA BAY LIFETIME WARRANTY CONSTRUCTION AND MANUFACTURER DEFECTS LIFETIME WARRANTY STAINLESS STEEL COMPONENTS TWO 2 YEAR WARRANTY GAS VALVE PILOT ASSEMBLY POWER SUPPLY CONTROLS TWO 2 YEAR...

Page 17: ...o repair the defect on warranty parts to and from the factory will be the responsibility of the owner We will not be responsible for labor charges and or damage incurred in installation repair and rep...

Page 18: ..._______ 2 Serial Number ___________________________ 3 How long is the gas line run Nat Gas ____ LP Gas ____ 4 What size is gas line _____ 5 Inlet Gas Pressure _____WC Manifold Gas Pressure _____ WC 6...

Reviews: