Fire Ring Burners

GAS PIPE SIZING CHART

REFERENCE

GAS PIPE SIZING

Length of Pipe in Feet

1/2”

3/4”

1”

1 - 1/4”

1 - 1/2”

2”

2 - 2 1/2”

3”

4”

10

275

567

1071

2205

3307

6221

10140

17990

35710

20

189

393

732

1496

2299

4331

7046

12510

25520

30

152

315

590

1212

1858

3465

5695

10110

20620

40

129

267

504

1039

1559

2992

4778

8481

17300

50

114

237

448

913

1417

2646

4343

7708

15730

60

103

217

409

834

1275

2394

3908

6936

14150

70

89

185

346

724

1086

2047

3329

5908

12050

80

78

162

307

630

976

1811

2991

5309

10830

90

69

146

275

567

866

1606

2654

4711

9613

100

63

132

252

511

787

1496

2412

4281

8736

125

54

112

209

439

665

1282

2083

3618

7382

150

48

100

185

390

590

1138

1808

3210

6549

175

43

90

168

353

534

1030

1637

2905

5927

200

40

83

155

325

491

947

1505

2671

5450

300

37

77

144

303

458

887

1404

2492

5084

NATURAL GAS : PIPE SIZING CHART

Natural Gas (NG) flow is given in 
thousands of BTU/hr. = 1 cubic 
foot of NG gas - 1000 BTU

Nominal pressure at the burner 
for Natural Gas is 3.5” of water 
column. (Typical machine supply 
5”-7”)

Pipe length must include 
additional length for all fittings. 
Add approximately 5 feet of pipe 
per fitting.

Natural Gas Example: A machine 
with a burner that requires 
440,000 BTU would need a 1 -1/4” 
pipe for a 20” long run. 

LIQUID PROPANE : PIPE SIZING CHART

NOTE: The sizing charts above list the specific pipe sizes required for the amount of BTU’s for a new gas line installations. If you 
are using an existing gas line you must take into consideration the existing gas line capacities to ensure you will have proper 
pressure. 

This chart is for reference only, we recommend you consult with a Licensed Plumber/Gas Fitter or NFPA54 (National Fuel 

Gas Code - current edition) for more details.

Length of Pipe in Feet

1/2”

3/4”

1”

1 - 1/4”

1 - 1/2”

2”

2 - 2 1/2”

3”

4”

10

108

230

387

793

1237

2259

3640

6434

-

20

75

160

280

569

877

1610

2613

5236

9521

30

61

129

224

471

719

1335

2165

4107

7859

40

52

110

196

401

635

1143

1867

3258

6795

50

46

98

177

364

560

1041

1680

2936

6142

60

42

89

159

336

513

957

1559

2684

5647

70

38

82

149

317

476

896

1447

2492

5250

80

36

76

140

239

443

840

1353

2315

4900

90

33

71

133

275

420

793

1288

2203

4667

100

32

68

126

266

411

775

1246

2128

4518

125

28

60

117

243

369

700

1143

1904

4065

150

25

54

105

215

327

625

1008

1689

3645

175

23

50

93

196

303

583

993

1554

3370

200

22

47

84

182

280

541

877

1437

3160

300

17

37

70

145

224

439

686

1139

2539

Liquid Propane (LP) Gas flow is 
given in thousands of BTU/hr.  =
1 cubic foot of LP gas - 2500 BTU.

This chart refers to low pressure LP, 
after regulation, Standard nominal 
pressure at the burner for Liquid 
Propane Gas is 11” of water column.

Pipe length must include additional 
length for all fittings. Add 
approximately 5 feet of pipe per 
fitting.

LP Example: A machine with a 
burner that requires 440,000 BTU 
would need a 1” pipe for a 20’ long 
run. 

Table 4

 Gas Pipe Sizing Chart

Summary of Contents for FG-FR-12SS

Page 1: ...AD OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS DO NOT ATTEMPT TO INSTALL OR OPERATE THIS APPLIANCE DO NOT DISCARD THIS MANUAL HAS IMPORTANT OPERATING AND MAINTENANCE INSTRUCTIONS LEAVE WITH THE HOME...

Page 2: ...nt DANGER WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or other appliances Any LP cylinder not connected for use shall not be stored in the vicini...

Page 3: ...e potential to crack or pop outside the fire feature WE HIGHLY RECOMMEND COVERING ALL FIRE FEATURES WHEN NOT IN USE The use of a cover can lessen the impact of thermal spalling however heavy rains hig...

Page 4: ...lightly from Table 2 specifications BEFORE INSTALLING A FIRE RING DETERMINE PAN SIZE TO BE USED Fire Ring Kits listed above are not provided with a burner pan for installation We suggest you provide a...

Page 5: ...e LP fire pits do not use a Propane tank less than 100lbs capacity IMPORTANT Installation of Natural or LP gas should be done by a qualified installer service agency or gas supplier This appliance mus...

Page 6: ...ipe sizes required for the amount of BTU s for a new gas line installations If you are using an existing gas line you must take into consideration the existing gas line capacities to ensure you will h...

Page 7: ...10 This fire pit is designed to have Firegear Outdoors lava rock or glass media completely covering the burner tube so that the burner is not visible Do not cover more than 1 above the top of burner...

Page 8: ...and LP Gas Ensure to seal each NPT fitting with thread tape or pipe compound NOTE Flared fittings will not require tape or compound on the flared side Step 1 Install plug on top of fire ring and assem...

Page 9: ...nsure the center hole is a minimum of 1 inch in diameter See Fig 9 Models FG FR 30SSK FG FR 36SSK and FG FR 48SSK come with a plug nipple OAS and FIP x MIP flare fittings U3 8E S and to reducer S4100...

Page 10: ...a i l Fig 12 Typical installation NOTE Key valve and flexible gas lines are supplied Gas shut off is not supplied Note A 1 x 2 black iron or galvanized coupler nipple not supplied can be used as a spa...

Page 11: ...use of the appliance 6 Temporary storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply Natural or L P gas line WARNING 1 This appliance is hot when ope...

Page 12: ...REV B Page 12 Fire Ring Burners FIRE RING REPLACEMENT PARTS 2 3 Drawings not to scale 6 4a O N O F F 1 7 5 4c 4b...

Page 13: ...rifice Air Shutter NG 250 000 Btu s Used with FG FR 30SSK 1 OAS NG25 64 2 Orifice Air Shutter NG 250 000 Btu s Used with FG FR 36SSK 1 OAS NG25 64 2 Orifice Air Shutter NG 250 000 Btu s Used with FG F...

Page 14: ...Burners 12 inch Key T200 9898 28 Key Valve U1 8D S Flange GAS FLOW OAS U3 8D S Fire Ring Burner Plug Nipple MODELS FG FR 6SSK FG FR 12SSK FG FR 18SSK FG FR 24SSK Fire Ring Contents MODELS FG FR 30SSK...

Page 15: ...the opposite direction see Fig 17 or 17 A 90 elbow or close nipple are not provided with the kit All NPT pipe threads must be sealed with approved gas Teflon tape or pipe compound Check for any gas l...

Page 16: ...1 Cubic Foot Model FG LAVA 40 Paver Control Panels PAVER CP MT MT systems Fireglass Liquid Glass Reflective Glass Sold in 10lb jugs in various colors See your Firegear dealer for various options Log S...

Page 17: ...t is found faulty must be replaced with an approved component 3 Any tampering or modifying with the fire pit is dangerous and voids all warranties 4 During winter months in cold climates and various s...

Page 18: ...ANTY REFRACTORY GAS LOG SETS FIVE 5 YEAR WARRANTY READY TO FINISH ANF FIRE PIT ENCLOSURES FIVE 5 YEAR WARRANTY SKYTECH MANUACFTURED OPTIONAL CONTROLS OUTDOOR FIREPLACE KALEA BAY LIFETIME WARRANTY CONS...

Page 19: ...EA BAY LIFETIME WARRANTY CONSTRUCTION AND MANUFACTURER DEFECTS LIFETIME WARRANTY STAINLESS STEEL COMPONENTS TWO 2 YEAR WARRANTY GAS VALVE PILOT ASSEMBLY POWER SUPPLY CONTROLS TWO 2 YEAR WARRANTY SKYTE...

Page 20: ...defect on warranty parts to and from the factory will be the responsibility of the owner We will not be responsible for labor charges and or damage incurred in installation repair and replacement Fir...

Page 21: ...or consequential damages so this limitation or exclusion may not apply to you We do not authorize any person or company to assume for it any other obligation or liability in connection with the sale...

Reviews: