CLEARANCE TO COMBUSTIBLE DECORATIVE SURROUNDS
Decorative surrounds i.e. timber
mantelpieces/combustible moulding must be
50mm (min) clear of the face side edges and top
face edge of the firebox.
Upright legs and breast sections of
combustible surrounds must not project further
than 50mm (max) forward of the face of the firebox.
Mantle shelves must be 300mm (min)
clear above the top edge of the firebox and must
not project more than 250mm (max) forward of
the face of the firebox.
A non-combustible floor protector
(forehearth) at the base directly in front of the
firebox opening must be a minimum of 6mm
thick, project a minimum 300mm forward and
200mm on each side of the firebox opening.
MANTLEPIECE BREAST
GE
L
05
NI
M
50
MIN
50
MAX
250
MAX
00
3
NI
M
FIREFOX
OGF UNIT