The meter can still work if the input is higher than 10Vrms, but the 

accuracy is not guaranteed. 

In an RFI noise environment, you should use shielded cable to measure 

a low signal. 

When measuring high voltage circuits, no part of your body should 

touch the high voltage circuit. 

Never input a voltage higher than 250V DC or AC peak value, or it may 

damage the meter. 

Summary of Contents for Victor 88E

Page 1: ...1 User s Manual for Victor 88E Digital Multimeter Distributed and Copyrighted by www FiredragonEnt com...

Page 2: ...2...

Page 3: ...ACV DCA ACA resistance capacitance frequency temperature duty cycle and diodes and acts as a continuity performance tester The meter can provide functions including analog bar and unit symbol display...

Page 4: ...k the connection and insulation of test leads to avoid electric shock 2 Do not input a limited voltage higher than DC 1000V or AC 750V when measuring 3 When measuring voltage higher than DC 60V AC 40V...

Page 5: ...symbol display Measurement method double integral A D conversion Sampling rate approximately 3 times sec Over range display OL displayed in the highest digit Low battery display Working environment 32...

Page 6: ...ure Probe Duracell batteries and P25 hard case The Victor 88E C comes with Standard Package L36 Test Leads FSG1 Flame Safeguard Adapter GA1 and GA2 Gas Burner Thermocouple Adapters PT1 Probe Pins and...

Page 7: ...1 0 4 1V Input impedance 400mV Range 10M other range is 40M Overload protection 1000V DC or 750V AC AC Voltage ACV Range Accuracy Resolution 400mV 1 5 6 0 1mV 4V 0 8 6 1mV 40V 10mV 400V 100mV 750V 1 0...

Page 8: ...seconds Overload protection 400mA 250V and 20A 250V fast acting fuse AC Current ACA Range Accuracy Resolution 400uA 1 5 5 0 1 A 4000uA 1 A 40mA 10 A 400mA 100 A 20A 2 0 15d 10mA MAX measurement voltag...

Page 9: ...protection 250V DC or AC peak value NOTE At a range of less than 400 short circuit the test leads to measure the wire resistance and then subtract it from the real measurement Capacitance C Range Acc...

Page 10: ...value Diode and continuity performance test Range Value displayed Testing condition Forward voltage drop of diode Forward DCA is approx 0 5mA the backward voltage is approx 1 5V Buzzer makes a long so...

Page 11: ...nge Accuracy Resolution 40 C 1000 C 0 C 1 0 4 0 C 400 C 1 0 4 400C 1 5 15 1 C 0 F 1832 F 750 F 0 8 5 750 F 1 5 15 1 F Sensor TP01 K type thermocouple CAUTION DO NOT INPUT VOLTAGE WHEN OPERATING IN THI...

Page 12: ...it will return to auto range mode 2 3 HOLD key press it the presently measured value is held on LCD and HOLD symbol displays Press it again HOLD symbol disappears and the meter exits the holding mode...

Page 13: ...suring the Frequency it will switch frequency duty cycle 1 99 3 Selector Knob Selects measuring function and range 4 TERMINAL Temperature and V Hz Voltage Resistance Frequency Capacitor and Temperatur...

Page 14: ...l across the electric circuit under test LCD displays polarity and voltage under test connected by the red test lead Note 1 Users should first set the select knob to the correct range if users have no...

Page 15: ...RANGE key will display AC mV range 4 Connect the leads in parallel across the electric circuit under test LCD displays voltage by the test lead Note 1 Users should first set the selector knob to the...

Page 16: ...n connect the leads in series into the electric circuit under test LCD displays current under test Note Users should first set the selector knob to the highest range if users have no idea about the ra...

Page 17: ...the highest range if users have no idea about the range of current under test and then select the proper range based on displaying value 2 If the LCD displays OL it means the current is over range Now...

Page 18: ...This is normal for high resistance measuring 2 When the input lead is in an open circuit overload displays OL 3 When measuring in line resistors be sure that the power is off and all capacitors are c...

Page 19: ...acitors The capacitance must be complete discharged before testing to protect the meter A reading over the 400uF range will delay 15 seconds Frequency Measurements 1 Insert the black lest lead into th...

Page 20: ...s not guaranteed In an RFI noise environment you should use shielded cable to measure a low signal When measuring high voltage circuits no part of your body should touch the high voltage circuit Never...

Page 21: ...red test connected to the diode cathode polarity and the black test lead to the diode positive polarity the LCD will display OL 4 This will complete diode testing including forward and backward measu...

Page 22: ...the object to be tested Read the temperature from the screen and the data is in Centigrade 3 Press the SELECT key to select Fahrenheit the data is in degrees Fahrenheit Note 1 When the input terminal...

Page 23: ...er powers off Press any key to restart the power Meter Maintenance The 88E is a high accuracy precision instrument please do not attempt to modify any of the internal circuits 1 Keep the meter away fr...

Page 24: ...Never measure a voltage with the meter selector knob in the current resistance temperature capacitance or diode and continuity range 3 Never use the meter without a battery installed and the back case...

Page 25: ...fications are subject to change without notice We hereby will not be responsible for any accident and damage caused by improper operation The functions stated in this User Manual cannot be exceeded by...

Page 26: ...ning To prevent electric shock fire and personal injury carefully read all safety information before attempting to operate the current Clamp and follow these procedures Do not use the clamp on circuit...

Page 27: ...F 30 C to 40 C 75 RH 104 F to 122 F 40 C to 50 C 45 RH Storage conditions 22 F to 140 F 30 C to 60 C 90 Relative Humidity Altitude Operate at less than 9800 feet or 3000 meters Weight 4 5 ounces Dimen...

Page 28: ...t to select AC push SELECT button on 88E Position the Klamp jaw perpendicular to and centered around the conductor to be measured Read the measured value from the 88E LCD display Example for using mul...

Page 29: ...ll powerburner PSC motor multimeter reads 1 30 mV actual reading is 1 3 amps Figure 2 Description of Amp Klamp 88CP9 1 Current sensing jaw 2 Klamp trigger to open 3 Safety barrier 4 Voltage output lea...

Page 30: ...30...

Reviews: