Firecraft Superior Standard BBV-42REN Homeowner'S Care And Operation Instructions Manual Download Page 12

12

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

A.

When lighting the appliance, follow these instructions
exactly.

B.

BEFORE OPERATING smell all around the appliance area
for gas. Be sure to smell next to the floor because some
gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Extinguish any open flame.

Open windows.

Do not light any appliance.

Do not touch any electrical switches.

Do not use any phone in your building.

FOR YOUR SAFETY READ BEFORE LIGHTING

Immediately call your gas supplier from a neighbor’s
phone.

If your gas supplier cannot be reached, call the fire
department.

C.

 Use only your hand to turn the gas control lever. Never

use tools. If the lever will not turn by hand, do not try to
repair it, call a qualified service technician. Force or
attempted repair may result in a fire or an explosion.

D.

 Do not use this appliance if any part has been under

water. Immediately call a qualified service technician to
inspect the appliance and to replace any part of the
control system and any gas control which has been
under water.

LIGHTING INSTRUCTIONS — ELECTRONIC

1.

For complete shut-down, turn remote wall switch to
“OFF.”

2.

Open lower control compartment door.

3.

Turn the ON/OFF switch to “OFF”. Do not force.

4.

Close the main line shut-off valve.

5.

Close lower control compartment door.

TO TURN OFF GAS TO APPLIANCE

LIGHTING INSTRUCTIONS

1. STOP!

 Read the safety information above on this page.

2.

Turn remote wall switch to “OFF.”

3.

Open lower control compartment door.

4.

Verify main line shut-off valve is open.

5.

Turn the ON/OFF switch to “OFF”.  Do not force.

6. 

 Wait five (5) minutes to clear out any gas. If you then

smell gas, STOP! Follow “B” in the safety information
above on this page. If you do not smell gas, go to the
next step.

7.

Turn the ON/OFF switch to “ON”.  Do not force.

8.

Turn “ON” all electrical power to appliance (remote wall
switch).

9.

Close lower control compartment door.

TO SHUT OFF

1.

Turn off all electrical power to the appliance (remote wall
switch).

Front View

ON/OFF Switch

OFF

I

P

S

I

ON

CONTROL

IG
N

IT
E

Summary of Contents for Superior Standard BBV-42REN

Page 1: ...ING IFTHEINFORMATIONINTHISMANUAL IS NOT FOLLOWED EXACTLY A FIRE OR EXPLO SION MAY RESULT CAUSING PROPERTY DAM AGE PERSONAL INJURY OR LOSS OF LIFE POURVOTRES CURIT Nepasentreposerniutiliser d essenceni...

Page 2: ...ts These appliances comply with National Safety Standards and are tested and listed by Report No J99025850 to ANSI Z21 50b 1998 in Canada CAN CGA 2 22b M98 as vented gas fireplaces Installation must c...

Page 3: ...d ornau sea If you have these signs obtain fresh air immediately Turn off the gas supply to the appliance and have it serviced by a qualified professional as it may not be operating correctly WARNING...

Page 4: ...fore re light ing refer to the lighting instructions in this manual Instructions are also found on a pull out panel located on the floor of the appliance 5 Always keep the appliance area clear and fre...

Page 5: ...actuator forward to open the combustion air door and push it back to close To lock the outside air door closed ensure the actuator is pushed all the way back then push the end of the actuators to the...

Page 6: ...ICAL POWER BEFORE SERVICING THE APPLIANCE Millivolt Appliance Checkout The pilot flame should be steady not lifting or floating Flame should be blue in color with traces of orange at the outer edge Th...

Page 7: ...g Person Procedure Inspecting Cleaning Burner Logs and Controls Check Flame Patterns and Flame Height Inspecting Cleaning Pilot and Burner Checking Vent System Appliance Checkout Replacing Rockwool Em...

Page 8: ...es Figure 11 Spread along the front edge of the front burner Do not use more than is necessary When properly positioned the rockwool will unevenly cover approximately 85 of the gap between the front b...

Page 9: ...ile TH TP TH TP Limit Switch 1 If any of the original wire as supplied must be replaced 1 it must be replaced with Type AWM 105 C 18 GA wire 2 120V 60Hz Less than 3 amps BK Junction Box Transf 120 V 2...

Page 10: ...l switch OFF The pilot will remain lit for normal service 2 For complete shutdown turn remote wall switch to OFF 3 Access the lower control compartment 4 Depress gas control knob slightly and turn clo...

Page 11: ...r de l apareil ainsi que pr s du sol certains gaz tant plus lourds que l air descendent au niveau du sol VOICI CE QUE VOUS DEVEZ FAIRE SI VOUS D CELEZ UNE ODEUR DE GAZ teignez toute flamme visible Ouv...

Page 12: ...use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which ha...

Page 13: ...faire inspecter l appareil et remplacer toute pi cedusyst meder glageoucommandedugazquia t sous l eau 1 ARR TEZ Lisez les consignes de s curit au verso de cette plaque 2 Tournez l interrupteur mural l...

Page 14: ...k If gap measures replace pilot Figure 8 Check inlet gas pressure It should be within the limits as marked on the rating plate Clean or replace pilot orifice Check pilot flame it must impinge on therm...

Page 15: ...heck For Proper Voltage At Control Harness See Insert A Voltage Should Be 24V Between Thermostat Or Pressure Switch And 24V Common And 24V Hot Line Voltage Power Low Voltage Transformer Limit Controll...

Page 16: ...e part 5 The quantity required 6 The installation date of the appliance If you encounter any problems or have any questions concerning the installation or appli cation of this system please contact yo...

Page 17: ...spressed asignallightilluminates briefly to verify that a signal has been sent The Model RCK S is designed to operate with all millivolt ignition systems as well as elec tronic ignition systems It may...

Page 18: ...ssembly LB 97338 1 LB 97338 1 10 Burner Orifice 18L4001 1 LB 558741 1 11 Bag of Rockwool 88L53 1 88L53 1 GAS CONTROLS ELECTRONIC Natural Propane No DESCRIPTION Part No Qty Part No Qty 30 Gas Valve Hon...

Page 19: ...19 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE REPLACEMENT PARTS 24 22 20 3 4 5 6 7 2 1 31 30 10 REF 10 21 25 26 23 33 9 8 11 32 c b a d e...

Page 20: ...2000 4325 Artesia Avenue Fullerton CA 92833 714 521 7302 FireCraft Technologies reserves the right to make changes at any time without notice in design materials specifications prices and also to disc...

Reviews: