Firecraft Superior Standard BBV-42REN Homeowner'S Care And Operation Instructions Manual Download Page 1

1

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

HOMEOWNER'S CARE AND
OPERATION INSTRUCTIONS

42" B-VENTED GAS APPLIANCES
P/N 725,007M  REV. N/C  08/2000

Millivolt Models

Electronic Models

BBV-42RMN

BBV-42REN

BBV-42RMP

BBV-42REP

MODELS

RETAIN THESE INSTRUCTIONS

FOR FUTURE REFERENCE

WH Report No. J99025850

FOR YOUR SAFETY:  Do not store or use gasoline
or other flammable vapors or liquids in the vicin-
ity of this or any other appliance.

FOR YOUR SAFETY:  What to do if you smell gas:

• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• DO NOT use any phone in your building.
• Immediately call your gas supplier from a

neighbor’s phone.

Follow your gas suppliers instructions.
• If your gas supplier cannot be reached, call the

fire department.

Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.

WARNING: IF THE INFORMATION IN THIS MANUAL
IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING PROPERTY DAM-
AGE, PERSONAL INJURY OR LOSS OF LIFE.

POUR VOTRE SÉCURITÉ:  Ne pas entreposer ni utiliser
d'essence ni d'autre vapeurs ou liquides inflammables
dans le voisinage de cet appareil ou de tout autre
appareil.

POUR VOTRE SÉCURITÉ:  Que faire si vous sentez une
odiur de gaz:

• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur.  Ne pas vous servir

des téléphones se trouvant dans le batiment où
vous vous trouvez.

• Evacuez la piéce, le bâtiment ou la zone.
• Appelez immédiatement votre fournisseur de gaz

depuis un voisin.  Suivez les instructions du
fournisseur.

• Si vous ne pouvez rejoindre le fournisseur de gaz,

appelez le service dos incendies.

L'installation et service doit être exécuté par un
qualifié installeur, agence de service ou le fournisseur
de gaz.

AVERTISSEMENT: ASSUREZ-VOUS DE BIEN SUIVRE
LES INSTRUCTIONS DONNÉ DANS CETTE NOTICE POUR
RÉDUIRE AU MINIMUM LE RISQUE D'INCENDIE OU
POUR ÉVITER TOUT DOMMAGE MATÉRIEL, TOUTE
BLESSURE OU LA MORT.

STANDARD SERIES

Summary of Contents for Superior Standard BBV-42REN

Page 1: ...ING IFTHEINFORMATIONINTHISMANUAL IS NOT FOLLOWED EXACTLY A FIRE OR EXPLO SION MAY RESULT CAUSING PROPERTY DAM AGE PERSONAL INJURY OR LOSS OF LIFE POURVOTRES CURIT Nepasentreposerniutiliser d essenceni...

Page 2: ...ts These appliances comply with National Safety Standards and are tested and listed by Report No J99025850 to ANSI Z21 50b 1998 in Canada CAN CGA 2 22b M98 as vented gas fireplaces Installation must c...

Page 3: ...d ornau sea If you have these signs obtain fresh air immediately Turn off the gas supply to the appliance and have it serviced by a qualified professional as it may not be operating correctly WARNING...

Page 4: ...fore re light ing refer to the lighting instructions in this manual Instructions are also found on a pull out panel located on the floor of the appliance 5 Always keep the appliance area clear and fre...

Page 5: ...actuator forward to open the combustion air door and push it back to close To lock the outside air door closed ensure the actuator is pushed all the way back then push the end of the actuators to the...

Page 6: ...ICAL POWER BEFORE SERVICING THE APPLIANCE Millivolt Appliance Checkout The pilot flame should be steady not lifting or floating Flame should be blue in color with traces of orange at the outer edge Th...

Page 7: ...g Person Procedure Inspecting Cleaning Burner Logs and Controls Check Flame Patterns and Flame Height Inspecting Cleaning Pilot and Burner Checking Vent System Appliance Checkout Replacing Rockwool Em...

Page 8: ...es Figure 11 Spread along the front edge of the front burner Do not use more than is necessary When properly positioned the rockwool will unevenly cover approximately 85 of the gap between the front b...

Page 9: ...ile TH TP TH TP Limit Switch 1 If any of the original wire as supplied must be replaced 1 it must be replaced with Type AWM 105 C 18 GA wire 2 120V 60Hz Less than 3 amps BK Junction Box Transf 120 V 2...

Page 10: ...l switch OFF The pilot will remain lit for normal service 2 For complete shutdown turn remote wall switch to OFF 3 Access the lower control compartment 4 Depress gas control knob slightly and turn clo...

Page 11: ...r de l apareil ainsi que pr s du sol certains gaz tant plus lourds que l air descendent au niveau du sol VOICI CE QUE VOUS DEVEZ FAIRE SI VOUS D CELEZ UNE ODEUR DE GAZ teignez toute flamme visible Ouv...

Page 12: ...use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which ha...

Page 13: ...faire inspecter l appareil et remplacer toute pi cedusyst meder glageoucommandedugazquia t sous l eau 1 ARR TEZ Lisez les consignes de s curit au verso de cette plaque 2 Tournez l interrupteur mural l...

Page 14: ...k If gap measures replace pilot Figure 8 Check inlet gas pressure It should be within the limits as marked on the rating plate Clean or replace pilot orifice Check pilot flame it must impinge on therm...

Page 15: ...heck For Proper Voltage At Control Harness See Insert A Voltage Should Be 24V Between Thermostat Or Pressure Switch And 24V Common And 24V Hot Line Voltage Power Low Voltage Transformer Limit Controll...

Page 16: ...e part 5 The quantity required 6 The installation date of the appliance If you encounter any problems or have any questions concerning the installation or appli cation of this system please contact yo...

Page 17: ...spressed asignallightilluminates briefly to verify that a signal has been sent The Model RCK S is designed to operate with all millivolt ignition systems as well as elec tronic ignition systems It may...

Page 18: ...ssembly LB 97338 1 LB 97338 1 10 Burner Orifice 18L4001 1 LB 558741 1 11 Bag of Rockwool 88L53 1 88L53 1 GAS CONTROLS ELECTRONIC Natural Propane No DESCRIPTION Part No Qty Part No Qty 30 Gas Valve Hon...

Page 19: ...19 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE REPLACEMENT PARTS 24 22 20 3 4 5 6 7 2 1 31 30 10 REF 10 21 25 26 23 33 9 8 11 32 c b a d e...

Page 20: ...2000 4325 Artesia Avenue Fullerton CA 92833 714 521 7302 FireCraft Technologies reserves the right to make changes at any time without notice in design materials specifications prices and also to disc...

Reviews: