atmosphere, above the height of the
header tank. There should not be any
valves between the inset stove and
the vent pipe outlet and it must not
be possible to obstruct the outlet in
anyway.
11. Fit the flue connector to the top of the
appliance so that it is central to the
chimney and extends to the point
where the chimney narrows.
Ensure that the flue manufacturer’s
instructions are adhered to at all
times.
12. All voids must be filled and the flue
pipe flaunched into the chimney,
so that no soot can collect when
sweeping the chimney.
13. Make good the holes in the front and
side of the chimney breast, ensuring
they are airtight. Remove any material
from inside the appliance and check
the flue pipe is clear.
8
Vermiculite
Flue liner
Flue gatherer
Flue adaptor
Flexible liner
Inset stove
Fixing screws