background image

Technical Support Line 

0800 141 2561

 

UK Textphone users dial 

18001 0800 141 2561

 

EIRE dial 

1-800 523171

Email 

[email protected]

Web 

www.fireangel.co.uk

W2-SVP-630

Sprue Safety Products Ltd.
Vanguard Centre, Sir William Lyons Road, Coventry  CV4 7EZ  UK

A Sprue Safety Products Brand

GN2237/R2

Summary of Contents for W2-SVP-630

Page 1: ...roduct may be purchased from Connevans Limited secure online store at www DeafEquipment co uk DeafEquipment co uk Offering you choice Helping you choose Connevans info Solutions to improve the quality of life ...

Page 2: ...User Manual COMBINED STROBE VIBRATING PAD W2 SVP 630 Please read me as I could save your life Please retain this user manual for future reference ...

Page 3: ...Keeping you safe from fire and carbon monoxide For a full range of smoke alarms and carbon monoxide alarms visit www fireangel co uk ...

Page 4: ...OR CO ALARM 6 TESTING THE WI SAFE 2 STROBE AND VIBRATING PAD WITH SMOKE CO ALARMS 7 POSITIONING 8 INSTALLING THE STROBE 10 LIMITATIONS 11 OPERATION 12 UNPLUGGING FROM THE MAINS POWER CUT 13 PRODUCT INDICATORS LEDS 14 WHAT TO DO IF YOUR STROBE AND VIBRATING PAD GOES INTO ALARM 15 WHAT TO DO IN THE EVENT OF A SMOKE ALARM TRIGGERING THE STROBE AND PAD 16 WHAT TO DO IN THE EVENT OF A CARBON MONOXIDE A...

Page 5: ...Vibrating Pad will be triggered to alert someone who may not be able to hear the audible alarm The flashing strobe provides a visual warning for waking hours while the vibrating pad is designed to be placed under a pillow or a mattress and is suitable for waking an individual to alert them when a smoke alarm sounds If placed under a mattress ensure the thickness of the mattress does not cushion th...

Page 6: ...Wi Safe 2 range purchased separately Wi Safe 2 Strobe and Vibrating Pad Pack contains 1 CP STROBE Strobe light with integrated control unit referred to as strobe 2 CP VPAD Vibrating pad to be placed under pillow or chair referred to as pad 3 AD DC12V05A AC mains adaptor 12v 0 5A rated output 4 B 450L Replaceable rechargeable 5 year life battery 5 Wall fixing screws NOTE TheStrobeandVibratingPadiso...

Page 7: ...StrobeandVibratingPad NOTE Up to fifty Wi Safe 2 enabled Smoke alarms CO alarms and or Wi Safe 2 accessories can be interlinked learned in to a single network Ensure all smoke alarms and or CO alarms to be used are installed tested and working correctly as per the instructions in their respective user manuals It is possible to use the strobe independently For further details please contact Technic...

Page 8: ...ire to red wire and clipping the connectors together You may hear the Strobe chirp as you do this 7 Plug the mains adaptor into a 230V socket and turn the power on The green power LED should illuminate 6 Plug the power cable in to the Strobe Route the wire through the wire guide fig3 3 Place the battery into the recess NB the battery cable needs to be positioned underneath the battery Place the ca...

Page 9: ...isting Wi Safe 2 system You will use this product when adding the strobe into the network 2 Follow steps from point 2 above 3 After pressing this button the two Alarm red LEDs on the front of the unit will flash and then illuminate for 5 seconds 4 During this period while the red LEDs are illuminated press the test reset button on the Smoke or CO alarm to wirelessly interlink the two products The ...

Page 10: ... unlearn the Strobe from the wireless network 1 Briefly push and release the learn button located in the circular hole in the back of the Strobe as shown fig 4 The two red alarm LEDs on the front of the Strobe will illuminate as you push the button 2 Push and hold the learn button a second time The red alarm LEDs will illuminate Hold the button until the red alarm LEDs extinguish 3 The red alarm L...

Page 11: ...e alarms sound Both red alarm LEDs on the Strobe will flash for a short time This confirms that the units are wirelessly interlinked Weekly Testing It is recommended that a self test of all the units in your Wi Safe 2 network is carried out weekly TESTING THE WI SAFE 2 STROBE AND VIBRATING PAD WITH SMOKE CO ALARMS Testing the network from the Smoke Alarm or CO alarm Briefly press the test button o...

Page 12: ...CO within sufficient time to alert you of the danger and provide adequate time for your escape In order to maximise your level of safety always test your Strobe and Vibrating Pad and all alarms in the Wi Safe 2 network system every week to ensure the whole system is in full working order and that the wireless interlink RF between the alarms and ancillary products has not been compromised NOTE The ...

Page 13: ...below 5 C or rise above 40 C Anywhere where the units can easily be knocked or damaged It is important that if you install additional Strobes and Vibrating Pads you test each of these upon installation to check they are learned in to the rest of the network Wireless Range The wireless range of Wi Safe 2 products is over 200 metres in clear air clear line of sight However it is recommended not to e...

Page 14: ...ing In the pack you will find two screws and two screw anchors Push the screw anchors if needed into the drill holes and secure the screw leaving the heads protruding so that the face of the head is 5mm away from the wall Now hook the Strobe onto the screws see below If placing the Strobe on a table instead of mounting on the wall make sure it cannot be easily knocked or slide off The green Power ...

Page 15: ...Vibrating Pad is not compatible with products from the original Wi Safe product range The Strobe and Vibrating Pad will not operate in isolation with non Wi Safe 2 Alarms or any alarms made by other manufacturers The separate units making up the Strobe and Vibrating Pad cannot be interchanged with those of other manufacturers and an attempt to do this may render the whole system unsafe Do not conn...

Page 16: ...is will enable the instigating alarm to be identified located If necessary the instigating alarm can then be silenced The Strobe and Pad is designed to be mains powered The internal rechargeable battery will still provide power if the mains is disconnected A fully charged battery will allow the Strobe and Pad to continue to operateforthreedays NB Onlyusethebatterysupplied in the pack or a genuine ...

Page 17: ...ugged into mains Flashing once per second Reconnect vibrating pad to strobe Mains not connected and battery capacity low Strobe will chirp Flashing once every 5 secs URGENTLY restore power to unit as battery status is very low Alarm mode Smoke Strobe flashing pad vibrating Illuminated providing Strobe is plugged into mains Flashing Alarm CO Open windows and evacuate property Alarm mode CO Strobe f...

Page 18: ...th beep sequence Double flash not repeated Double flash not repeated Double flash not repeated None required WHAT TO DO IF YOUR STROBE AND VIBRATING PAD GOES INTO ALARM CAUTION In all circumstances assume your Strobe and Vibrating Alert is responding to a real alarm situation that has been triggered by either a smoke alarm or carbon monoxide alarm The type of incident triggering the Strobe and Vib...

Page 19: ...a cloth wet if possible Take short shallow breaths Keep doors and windows closed Open them only if you have to in order to escape Meet at your planned meeting place after leaving the house Carry out a head count Call the fire service on 999 as soon as possible from outside your house If possible use a neighbour s phone or call box rather than a mobile phone as the location can be traced from the n...

Page 20: ...M What to do during an alarm Keep calm and open the doors and windows to ventilate the property Stop using all fuel burning appliances and ensure if possible that they are turned off Evacuate the property leaving the doors and windows open Ring your gas or other fuel supplier on their emergency number keep the number in a prominent place Do not re enter the property until the alarm has stopped Whe...

Page 21: ... your Wi Safe 2 Strobe and Vibrating Pad is not working correctly and you are unable to resolve the problem after consulting the Troubleshooting section please contact Technical Support The battery provided has been chosen specifically for this application but will need to be replaced every 5 years under normal operating conditions If during normal operation i e connected to the mains supply for a...

Page 22: ...cal Support on 0800 141 2561 The power green LED is illuminated and the Fault amber LED is also continuously lit The strobe unit is not interlinked learned in to the rest of the network If you have learned in the unit and this is happening regularly call Technical Support on 0800 141 2561 The Strobe and Pad does not respond to a smoke or CO alarm that is being tested Check that the alarm and the s...

Page 23: ...date of purchase Sprue Safety Products Ltd at its discretion agrees to replace the unit free of charge The warranty on any replacement W2 SVP 630 will last for the remainder of the period of the original warranty in respect of the product originally purchased that is from the date of original purchase and not from the date of receipt of the replacement product Sprue Safety Products Ltd reserves th...

Page 24: ...unding devices For more details visit www sprue com breach of any expressed or implied warranty Except to the extent prohibited by applicable law any implied warranty of merchantability or fitness for a particular purpose is limited in duration for 5 five years This warranty does not affect your statutory rights Except for death or personal injury Sprue Safety Products Ltd shall not be liable for ...

Page 25: ...users dial 18001 0800 141 2561 EIRE dial 1 800 523171 Email technicalsupport fireangel co uk Web www fireangel co uk W2 SVP 630 Sprue Safety Products Ltd Vanguard Centre Sir William Lyons Road Coventry CV4 7EZ UK A Sprue Safety Products Brand GN2237 R2 ...