What To Do If You Smell Gas:

  Do not try to light any appliance.

  Do not touch any electrical switch; do not use any phone 

in your building.

  Immediately  call  your  gas  supplier  from  a  neighbour's 

phone. Follow the gas supplier's instructions.

  If  you  cannot  reach  your  gas  supplier,  call  the  Fire 

Department.

A. 

This appliance is equipped with an ignition system that allows 
for both continuous pilot operation as well as an electronic 
ignition that lights the pilot burner automatically. 

Do not attempt 

to light the pilot by hand.

B.  BEFORE LIGHTING

 smell all around the appliance area for 

gas.  Be sure to smell next to the floor because some gas is 
heavier than air and will settle on the floor.

1. 

Turn off remote switch.

2. 

Flip down the lower trim.

3. 

Turn the switch on the Control Module  to "Continuous Pilot 

Off".

4. 

Flip up the trim.

with American Flame Electronic Ignition

B-Series BF-A

ADJ.

AUX

Learn

Remote/Off

Continuous

Pilot Off/On

S

I

IPI

POWER

6VAC 200mA

AC ADAPTOR

Wall Switch (SWI)

Brown
Brown

Black

White

Green

White

Orange

Pilot

Main

Manual

Hi/Lo

Main Gas Input

Main Gas Output

White (Sensor)

Orange (Igniter)

Control

Module

Emergency

Battery

Power

(4 x AA)

Pilot Assembly

Red

Black

Red

Black

Optio

nal

L-Series DF-I

Lighting  Instructions:

To Turn Off Gas To Appliance:

1.

 

STOP!  

Read the safety information above on this label.

2.

  Flip down the lower trims.

3.

  If the switch on the control module is set to "Continuous Pilot 

Off" then the pilot will light when the appliance is turned on 
by the remote switch.  When switched to "Continuous Pilot 
On" then the control module will attempt to light the pilot until 
it detects that the pilot has been successfully lit.

4.

  With the control module set to "Continuous Pilot Off" wait 5 

minutes to clear out any gas.  If you smell gas,

 STOP! 

Follow 

"B" in the safety information above on this label.  If you don't 
smell gas, go to the next step.

5.

  Turn  switch  on  the  control  module  to  "Continuous 

Pilot  On"    This  will  initiate  the  lighting  of  the  pilot.

  

NOTE:

 This unit is equipped with an ignition system that lights 

the pilot burner automatically. 

Do not attempt to light the 

pilot by hand.

6.

  Turn on wall switch.

7.

  Flip up the lower trim.

8.

  If the fireplace does not operate, follow the instructions "To 

Turn Off Gas To Appliance" and call your service technician 
or gas supplier.

9.

  If you wish to operate the Fireplace without the Continous Pilot 

simply turn the switch on the control module to "Continuous 
Pilot Off" and follow instructions 6-8.

For Your Safety - READ BEFORE LIGHTING:

with American Flame  Electronic Ignition

Operation -  Model L38DF-ST-A 

WARNING:

 

If you do not follow these instructions exactly, a fire or explosion may 

result causing property damage, personal injury or loss of life.

L38DF-ST-A

Summary of Contents for L38DF-ST

Page 1: ...s supplier s instructions If you cannot reach your gas supplier call the fire department For Your Safety Do not store or use gasolineorotherflammable vapors and liquids in the vicinity of this or any...

Page 2: ...ted in this manual Consult your local Gas Inspection Branch on installation requirements for factory built gas fireplaces Installation repairs should be done by a qualified contractor Installations in...

Page 3: ...e clearances apply to all dimensions except the framed opening where the clearance to combustibles is 0 The L38DF ST clearance to unprotected combustible walls which are perpendicular to the fireplace...

Page 4: ...by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa Vent Installation This section cove...

Page 5: ...s in the termination MSR PTO 3F 5 8 PTO 3F 5 8 PTO 3F 5 8 PTKOG 5 8 1 Ensure that the two long mounting brackets are facing the bottom ofthetermination Seeinset Thiswillprovidemoreheatprotection at th...

Page 6: ...Venting runs must fall within the limits set by the venting graph see Figure 9a Figure 8 Retracted Installation using a combination of solid and flex venting Use the vent graph to determine your allow...

Page 7: ...ination PVTK 1 B Flex Sections PFL 1 12 Section PFL 2 24 Section PFL 3 36 Section PFL 4 48 Section C Rigid Sections PEXT 1 12 m f Section PEXT 2 24 m f Section PEXT 3 36 m f Section PEXT 4 48 m f Sect...

Page 8: ...ll flange of the vent termination is 156 this would be an acceptable installation Example B Acceptable Installation If the vertical dimension from the hearth is 72 and the horizontal run to the wall f...

Page 9: ...onents using the chart on Page 8 Figure 16 Extended horizontal installation using a combination of rigid and flex venting Figure 15 Heat Shield for short horizontal installation Install by slid ing ov...

Page 10: ...ace Note Flame characteristics will change if the maximum vent height is used Minimum clearance to combustible construction around the vent pipe is 1 on all sides must be maintained except on horizont...

Page 11: ...fireplace with a non combustible material Please Note The decorative facing materials may be subject to temperatures in excess of 250 F This should be considered when selecting facing materials We rec...

Page 12: ...oors Both Sides Typical Cautions DO NOT OPERATE THIS FIREPLACE WITHOUT THE GLASS DOOR OR WITH A BROKEN GLASS DOOR p Cautions 5 1 60 Supply G L1 L2 NOTE If any of the original wire supplied with the ap...

Page 13: ...Off Gas To Appliance Operation Model L38DF ST 3 Push in gas control knob slightly and turn clockwise to Off Do not force 4 Flip up the lower trim 1 Turn off remote switch 2 Flip down the lower trim 1...

Page 14: ...not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructio...

Page 15: ...ing Instructions To Turn Off Gas To Appliance 1 STOP Read the safety information above on this label 2 Flip down the lower trims 3 If the switch on the control module is set to Continuous Pilot Off th...

Page 16: ...o inspect the appliance and to replace any part of the control system and any gas control which has been under water p p p p p Operation Lighting Instructions See pages 13 to 15 Burner Adjustment The...

Page 17: ...s appear until the bubbling stops completely Figure 34 Pilot Burner Troubleshooting The following is a troubleshooting chart of possible problems PROBLEM CORRECTIVE ACTION Noisy Pilot Flame Locate pil...

Page 18: ...subjected to normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Appliance will prod...

Page 19: ...feet minimum in the United States 6 feet 1 8 m minimum in Canada L clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 16 inches 41 cm minimum f...

Page 20: ...rade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS...

Page 21: ...Part No XG0810 f i r e f e a t u r e Maintenance Notes Spare Parts L38DF ST L DF ST NG Gas Valve RGC1006 LP Gas Valve RGC1005 NG Pilot RPA020 LP Pilot RPA021 Burner NG RBL38501 Burner LPG RBL38502 ROR...

Page 22: ...Canadian Heating Products Inc Langley BC V4W 4A1 Montigo Del Ray Corp Ferndale WA 98248 XG0810 041808 f i r e f e a t u r e...

Reviews: