The termination cap
should be designed to
inhibit down-drafting
without restricting the
exhaust discharge.
For the best draw
the chimney
termination
should be at least
2 feet above the
highest portion
of the roof that
is within a 10
foot radius of the
chimney.
USE LISTED UL 103 TYPE
HT 2100 CHIMNEY ONLY.
When using a brick chimney, you must line the entire
chimney with stainless steel liner. The liner must be the
correct size for the furnace. (FC300F: 6 inch liner)
The diameter of the chimney stack should be consistent
throughout length of the chimney
The chimney size should be at least as large as the
exhaust stack on the furnace, but not more than twice
its size.
The chimney stack should have
a built in airtight clean out.