22
Problem: Down draft on chimney caused by one or more of the following.
• Cast iron damper in “CLOSED”
position.
• Open damper.
Possible Causes:
Remedies:
• Flue has a cold spot which
inhibits exhaust discharge from
rising properly.
• This problem may occur in factory built flues because the insulation
has settled or a seam has ruptured. In masonry flues, mortar loss
may be causing seepage of cooler outside air into the stack. Check
entire flue for structural integrity and leakage. Correct or repair as
needed, or replace or re-line the chimney.
• Remove obstruction.
• Increase chimney height.
• Open backdraft damper.
• There is an obstruction outside
chimney, such as a tree.
• Flue is located too close to the
peak of the roof or does not rise
above it to provide the proper
draft.
• Backdraft damper is in the
“closed” position.
10.
Problem: Circulation blower will not turn on.
Possible Causes:
Remedies:
• Defective capacitor.
• Replace capacitor.
• Contact your supplier for replacement.
• Review wiring diagram. If wired correctly, seek professional
assistance.
• Defective blower.
• Improper wiring.
11.
Problem: Bugs found in wood.
• Wood has rotted or has been
laying around for an extended
period of time.
• Inspect the wood for obvious signs of insect infestation such as
burrows or holes, avoid using if possible. Do not store wood indoors.
Possible Causes:
Remedies:
12.