f6.60 k-factor taBle (only for
frequency outPut)
K-Factor is the number of pulses which a sensor produces for one liter of
measured fluid. Here below all K-Factors for water at room temperature are
listed.
K-Factor values can depend on the installation conditions. K-Factor has to
divide the frequency generated by F6.60 in order to achieve the flow rate (l/s).
Please contact your dealer for K-Factor values not included in the table.
Installation on PVC pipes
ISo metric clamp Saddles for ISo SDr 21 pipes
(Pn10 up to d 90mm, Pn12,5 from d 110mm)
Part no.
Dn
d
k-factor
SCIC063BVC
50
63
39,88
SCIC075BVC
65
75
28,19
SCIC090BVC
80
90
19,55
SCIC110BVC
100
110
13,10
SCIC125BVC
110
125
10,11
SCIC140BVC
125
140
5,24
SCIC160BVC
150
160
4.01
SCIC200BVC
180
200
2,57
SCIC225BVC
200
225
2,03
SCIC063DVC
50
63
39,88
SCIC075DVC
65
75
28,19
SCIC090DVC
80
90
19,55
SCIC110DVC
100
110
13,10
SCIC125DVC
110
125
10,11
SCIC140DVC
125
140
5,24
SCIC160DVC
150
160
4.01
SCIC200DVC
180
200
2,57
SCIC225DVC
200
225
2,03
SMIC250IVC
225
250
1,64
SMIC280IVC
250
280
1,31
SMIC315IVC
280
315
1,03
ISo metric PVc tee fittings for ISo SDr 21
pipes (female ends for solvent welding)
Part no.
Dn
d
k-factor
TFIV20B
15
20
462,04
TFIV25B
20
25
272,89
TFIV32B
25
32
157,86
TFIV40B
32
40
101,60
TFIV50B
40
50
63,72
TFIV20D
15
20
462,04
TFIV25D
20
25
272,89
TFIV32D
25
32
157,86
TFIV40D
32
40
101,60
TFIV50D
40
50
63,72
PVc glue-on fittings
Part no.
Dn
d
k-factor
WAIV063
50
63
on request
WAIV075
65
75
on request
WAIV090
80
90
on request
WAIV110
100
110
on request
WAIV125
110
125
on request
WAIV140
125
140
on request
WAIV160
150
160
on request
WAIV200
180
200
on request
WAIV225
200
225
on request
WAIV250
225
250
on request
WAIV280
250
280
on request
WAIV315