MIN MODE
MAX MODE
Flow
Time
Hysteresis
Output relaxed
Output energized
Setpoint
Flow
Time
Hysteresis
Output relaxed
Output energized
Setpoint
outPut moDe
The F6.60 flow magmeter features 1 solid state relays and 1 analog output
4-20mA in addition to a Open Collector for frequency remoting (mainly for the
interfacing of F6.60 with a FLS monitor) and a Open Collector for the flow
direction remoting.
SSR output (connectors 5-6) can be set in the following way:
WINDOW OUT MODE
PULSE MODE
Flow
Time
Setpoint
Hysteresis
Hysteresis
Output relaxed
Output energized
Setpoint
Pulse duration
Volume
Volume
Volume
Pulse duration
Pulse duration
Output relaxed
Output energized
Flow
Time
Setpoint
Hysteresis
Hysteresis
Output relaxed
Output energized
Setpoint
WINDOW IN MODE