MAINTENANCE
TERMINATOR-1000
Rev. 000
20/12/04
30/35
5.2.6 BATTERIES
DISPOSAL
Old batteries are toxic wastes and they have to be thrown in a suitable and authorized place for the batteries
disposal. For a short storage, old batteries must be located in an authorized room. Moreover, they must be
stored in sealed plastic tanks, whose capacity is not lower than the electrolyte.
.
5.3 SUCTION MOTOR MAINTENANCE
The suction motor has to be checked up and cleaned. Every six months motor brushes have to be checked and
replaced if it is necessary.
To maintain the suction motor please follow the instructions below:
¾
Take the ignition key off the dashboard, disconnect the plug;
¾
Remove the steel plate that fixes the suction motor and the motor itself (see detail 4 in picture 5.11);
¾
Unscrew the fixing knobs (see detail 3 picture 5.11) and unthread the motor (see detail 2 picture
5.11);
¾
Remove the sponge filter under the motor, wash it and put it again in its position;
¾
Check the motor fan through the hole in the front side of the suction motor;
¾
Remove the plastic cover, loosen the screws and both the brushes supports and check the motor
brushes (see detail 1 in picture 5.11);
¾
Do now the opposite operations to set everything up again.
-
3
2
4
PICTURE N° 5.11
1