02-4211-200  05/09/01                                                                                                                                                                                                                                            7014228      314 SKMB 27 B

    "Mini Finn" Heater Installation & Operation Instructions

DIAGRAM 6

1

1   2   3   4   5   6

120V  AC

2

2 x 1500W  120V 

1

1 x 2100W  120V  
1 x 1700W  120V

a1

a1

b0

b0

a

b

a

b

M

V                      S

U                      R

2100W or
3000W

Timer
1h+9h  preset

N        L   Gr

1   2   3   4   5   6

240V  AC

3000W

L1   L2   Gr

4.7K        
 min. 
3.5W

1   2   3   4   5   6

L1   L2   Gr

2100W
240V AC

1 x 2100W
240V 

1

See Diagram 3 for supply connections copper wire size.

354 SKMB 8 F

Page 6   

Summary of Contents for FU21

Page 1: ...al temperature of the body dizziness lethargy drowsiness and fainting The effects of the hyperthermia include failure to perceive heat failure to recognize the need to exit the room unawareness of imp...

Page 2: ...2 DIAGRAM 3 MIN DISTANCE FOR THE MOUNTING BRACKETAND TO COMBUSTIBLE MATERIAL B Page 2 3 min A DISTANCE B DISTANCE C DISTANCE 21T 3 1 1 4 1 1 4 30T 3 1 1 4 2 1 2 HEATER MINIMUM Floor Area Ceiling Heigh...

Page 3: ...ctrical Code and local regulations Remove the heater s electrical box cover and connect the feed wires to the terminal block To determine the correct wire size refer to Diagram 3 Use copper supply wir...

Page 4: ...7 8 9 ONE HOUR OPERATING ZONE FOR 9 HOUR DELAY TIMER This area from OFF to ON is the operating zone This is the only time the heater is on DELAY ZONE This area from 9 to ON is the delay zone meaning...

Page 5: ...er which means you can set the heater to begin heating after a delay of up to 9 hours If you set the timer dial in the 1 to 9 zone the heater will automatically turn on after the selected delay time h...

Page 6: ...3 4 5 6 120V AC 2 2 x 1500W 120V 1 1 x 2100W 120V 1 x 1700W 120V a1 a1 b0 b0 a b a b M V S U R 2100W or 3000W Timer 1h 9h preset N L Gr 1 2 3 4 5 6 240V AC 3000W L1 L2 Gr 4 7K min 3 5W 1 2 3 4 5 6 L1...

Page 7: ...at the cycle 2 or 3 times end with a brisk shower rinse in cool water Dress when completely dry and perspiration has stopped Some sauna bathers enjoy the soothing effect of steam by splashing water on...

Page 8: ...Finn Heater Installation Operation Instructions DIAGRAM 7 DIAGRAM 8 TYPICAL PRE CUT WALL CONSTRUCTION 2x4 framing 1 2 wallboard fiberglass insulation 1 2 wallboard T G soft wood foil vapor barrier Loc...

Page 9: ...es spring or gravity loaded closures The door must always open outwards No shower can be installed in a sauna room No electrical receptacle shall be installed inside the sauna room The enclosed WARNIN...

Page 10: ...ts open when the sauna is not in use Saunas that are in daily use should be washed down at least once a week to keep them clean and the air fresh Duckboard should be removed from the sauna the sauna f...