![Finn HydroSeeder T90 Operator Instructions And Parts Manual Download Page 53](http://html1.mh-extra.com/html/finn/hydroseeder-t90/hydroseeder-t90_operator-instructions-and-parts-manual_2290159053.webp)
47
CLEANING AND MAINTENANCE (CONTINUED)
WEEKLY OR EVERY 40 HOURS OF OPERATING TIME
1. Clean air cleaner by following the instructions in the engine operator’s manual.
2. Lubricate all points on HydroSeeder
®
as outlined in DAILY CLEANING AND
MAINTENANCE SECTION. Additionally, lubricate the four grease fittings on clutch/pump.
3. Check the oil level in the hydraulic oil reservoir; maintain level with the sight gauge.
4. Check the slurry pump clutch adjustment to ensure that it snaps in and out of engagement.
Adjust the clutch with the engine off.
5. Check the antifreeze in radiator.
6. Inspect slurry tank for build-up of residue in suction area and clear if necessary.
7. Check and clean engine radiator. Flush with clear, low-pressure water and blow dry with
compressed air. Do NOT use high-pressure water spray or damage to the radiator fins will
occur.
SEASONAL AND WINTER STORAGE MAINTENANCE
1. Drain slurry tank of all water, prior to storage, and leave drain plug off while in storage.
2. Park unit in suitable location and chock wheels to prevent inadvertent movement.
3. If possible, cover machine with tarp or park inside of an enclosure.
4. Store the HydroSeeder
®
with all slurry valve handles in the open position. To prevent
damage from freezing, it is advisable to remove all slurry valves and store in a heated
area.
5. Pour 1 qt. (0.95 L) of mineral oil or environmentally safe lubricant into the pump housing
and spin pump by hand to prevent rust in the pump. Remove drain plug.
6. Chip and steel-brush any interior rust spots in the slurry tank and touch-up with paint.
See steps 2 and 3 in IV. MAINTENANCE of the HYDROSEEDER
®
SAFETY SUMMARY
SECTION.
7. Lubricate all fittings.
8. Check anti freeze in radiator.
9. Lubricate equipment again just prior to putting into operation after having been in storage.
10. Change hydraulic oil and filter. (400 hours)
11. Disconnect battery cables. In cold weather, remove battery and store it in a safe, warm
place.
12. Add fuel stabilizer to fuel tank.