background image

www.finglai.com

  Fault query 

1. If the switch set to on, but don't switch on when time reach, or set to off, but don't switch off when 
time reach, check the "week" whether it is correct, if wrong, please re-adjust. 
2. If you confirm the "on" and "off" time is completely correct, but the switch is on or off when it is not at 
the set time, please check the rest set time group, whether it is eliminated, if not, please clear it by the 
"use method" (Please note that the switch time display "_ _: _ _" mean to clear, if 0:00, it is not clear) 
3. If the above two are all correct, and the switch is still not normal action, please check whether it is in 
"automatic" work. 
 

  Note 

1. In order to prevent the heat, caused by strong current, the wires must be tightened to the terminal 
screws. 
2. Do not use this control switch for such equipment (such as medical equipment and large equipment, 
etc.) that may cause life-related accidents or have a significant impact on society due to errors. 
3. Do not touch the terminal after turning on the power. 
4. The product should work in the absence of moisture, corrosion and heavy metal content of the gas 
environment, do not contaminate the oil or water. 
5. Warranty is one year. 

Summary of Contents for KG316T

Page 1: ...range 12 48VDC 110 380VAC 3 Maximum contact allowable current 10A or 25A resistive 4 Power consumption 1 5W 5 Time control range 1min 168h 6 Timing error less than 2s per day 7 Ambient temperature 15 45 8 Ambient humidity 95 9 Dimensions 120x70x51mm 10 Product net weight A305G B175G The normal working conditions and installation conditions 1 Ambient air temperature is 25 40 and the average tempera...

Page 2: ... each time Press the Clock key to return the time when the number of switches is set D When set error or want to cancel the redundant settings Press the Cancel Resume button to cancel the setting press the Cancel Resume button again to restore the canceled settings E press the set button press the D key you can set the same daily time or different daily time Monday to Friday the same Monday throug...

Page 3: ...pliance to expand Wiring method as shown in Figure 2 in Load KM N KG316T out N Power 3 Three phase work wiring The controlled appliance is powered by a single phase need for external three phase AC contactor A As shown in Figure 3 The AC Control s coil voltage is AC220V 50HZ out N KG316T Load KM N A in B N C B As shown in Figure 4 AC Control s coil voltage is AG380V 50HZ out N KG316T Load KM N A i...

Page 4: ...an to clear if 0 00 it is not clear 3 If the above two are all correct and the switch is still not normal action please check whether it is in automatic work Note 1 In order to prevent the heat caused by strong current the wires must be tightened to the terminal screws 2 Do not use this control switch for such equipment such as medical equipment and large equipment etc that may cause life related ...