 Characteristics 

1. Every day or every week with 16 times ON/OFF; 
2. The switch time can be cycle by day or week; 
3. The longest control time is 168 hours, the shortest control time is 1 minute 
 

 Use the method 

If  you  use  this  product  in  your first  time,  can  click  on  the  “C”  key  by  a  small  wood,  which  is  mean 
restore the factory state. 
1. Time setting 
Hold the "clock" button then press "H-", "M+", "D+" key to adjust hour, minute, week. 
 
2. Set regular time 
A. Press the "P" key, the bottom left of the display shows "1 

次开

" words (mean the first time to open). 

Press the "H-", "M+", "D+" keys, enter the required opening time. 
B. then click the "P" key, the bottom left of the display "1 

次关

" words (mean the first off time). And 

then press the "H-", "M+", "D+" key, enter the required closing time. 
C. Continue to press the "P" key, the bottom left of the display will be displayed 

“2

次开

  ... 16

次开

, 16

次关

” ordinally, refer to the above "A, B" step, set each time. Press the "Clock" key to return the time 

when the number of switches is set. 
D. When set error or want to cancel the redundant settings, Press the "Cancel / Resume" button to 
cancel the setting, press the "Cancel / Resume" button again to restore the canceled settings. 
E. press the "set" button, press the "D+" key, you can set the same daily time or different daily time. 
Monday to Friday the same, Monday through Saturday or Saturday to Sunday the same or different 
cycle. 

Chinese 

code 

 

 

 

 

 

 

 

English 

meaning 

Monday 

Tuesday 

Wednesday 

Thursday 

Friday 

Saturday 

Sunday 

F. control mode selection: 
Press "manual / automatic" button, the bottom of  the display will  be displayed "

", "

自动运行

", "

words, said the selected control output. "

自动运行

" is the automatic control mode, and the output time 

is controlled by the set time. 

 

 Wiring (N mean neutral wire, L mean fire wire) 

1, The direct control of the wiring: Control of the electrical appliances are single-phase power supply, 
power  consumption  does  not  exceed  the  rated  capacity  of  the  switch,  can  be  used  direct  control, 
wiring as shown in Figure 1: 

N

P

ow

er

in

Load

N

KG316T

out

 

 
 
 
 
 

Summary of Contents for KG316T

Page 1: ...range 12 48VDC 110 380VAC 3 Maximum contact allowable current 10A or 25A resistive 4 Power consumption 1 5W 5 Time control range 1min 168h 6 Timing error less than 2s per day 7 Ambient temperature 15 45 8 Ambient humidity 95 9 Dimensions 120x70x51mm 10 Product net weight A305G B175G The normal working conditions and installation conditions 1 Ambient air temperature is 25 40 and the average tempera...

Page 2: ... each time Press the Clock key to return the time when the number of switches is set D When set error or want to cancel the redundant settings Press the Cancel Resume button to cancel the setting press the Cancel Resume button again to restore the canceled settings E press the set button press the D key you can set the same daily time or different daily time Monday to Friday the same Monday throug...

Page 3: ...pliance to expand Wiring method as shown in Figure 2 in Load KM N KG316T out N Power 3 Three phase work wiring The controlled appliance is powered by a single phase need for external three phase AC contactor A As shown in Figure 3 The AC Control s coil voltage is AC220V 50HZ out N KG316T Load KM N A in B N C B As shown in Figure 4 AC Control s coil voltage is AG380V 50HZ out N KG316T Load KM N A i...

Page 4: ...an to clear if 0 00 it is not clear 3 If the above two are all correct and the switch is still not normal action please check whether it is in automatic work Note 1 In order to prevent the heat caused by strong current the wires must be tightened to the terminal screws 2 Do not use this control switch for such equipment such as medical equipment and large equipment etc that may cause life related ...

Reviews: