10
CONTENTS
485-
485+
GND
BUT
SEN
NO
COM
NC
AL-
AL+
ACCESS CONNECTION PORT
Release
button
Door
sensor
+
-
2
3
A
C
EM lock
(NC)
Emergency
break glass
(NC)
Key switch
(NC)
NOTE
Please refer to AdapTec AC Installer Manual if you are using AdapTec AC.
DC12V
Power Supply
+12V
GND
POWER SUPPLY PORT
485-
485+
GND
BUT
SEN
NO
COM
NC
AL-
AL+
ACCESS CONNECTION PORT
Release
button
Door
sensor
DC12V
Power Supply
+12V
GND
POWER SUPPLY PORT
+
-
1
3
B
D
EM lock
(NO)
Emergency
break glass
(NO)
Key switch
(NO)
GND
BUT
NO1
COM1
NC1
Optional to use
with Diode
Door
lock
system
GND
BUT
NO1
COM1
NC1
Optional to use
with Diode
Door
lock
system
FOR NC (NORMALLY CLOSE) DOOR LOCK SYSTEM