12
ACCESS CONNECTION PORT
note
Please refer to AdapTec Plus Installer Manual if you are using AdapTec Plus.
POWER SUPPLY PORT
BELL-
BELL+
SEN
GND
BUT
NO1
COM1
NC1
AL+
AL-
ACCESS CONNECTION PORT
+
-
1
3
B
D
EM lock
(NO)
Emergency
break glass
(NO)
Key Switch
(NO)
Door bell
Release
button
BELL-
BELL+
SEN
GND
BUT
NO1
COM1
NC1
AL+
AL-
+
-
2
3
A
C
EM lock
(NC)
Emergency
break glass
(NC)
Key Switch
(NC)
Door bell
Release
button
Door
sensor
Alarm
device
DC12V
Power Supply
GND
+12V
GND
BUT
NO1
COM1
NC1
The use of Diode is
optional
Door
lock
system
POWER SUPPLY PORT
Door
sensor
Alarm
device
DC12V
Power Supply
GND
+12V
GND
BUT
NO1
COM1
NC1
The use of Diode is
optional
Door
lock
system
For nC (norMaLLy CLose) door LoCK systeM
For no (norMaLLy open) door LoCK systeM