background image

9

R

 Red

B

 Blue

G

 Green

 L 

-V 

+V

Power Supply/Power Input Module

AC110~240V

L  - Live

N - Neutral

E  - Earth

R

B

G

AdapTec Plus

Access Control/Power Output Module

 

 To Battery   Tamper  Siren 

EM 

 Output  

Siren 

Door 

 

Wiegand

      Switch 

Output 12V   

Voltage 

  Accept 

Exit 

  Input 

 -   +  Input   

  12V 

 0V 

 

 

GND WD0 WD1

Connection 

Points

GND

+12V

GND

WD0

WD1

DC 12V

Rechargeable

Backup 

Battery

Connection 

Points

Release

Button

 EM  +

 Lock  -

 Emergency  2
 Break
 Glass (NC)  3

 ON-OFF  C
 Key Switch
 (NC)  D

WIRING DIAGRAMS

 

R2, i-Kiosk100, i-Kiosk100 Plus, Q2i, Kadex
and m-Kadex

FUNCTION • 

Access Control Only or Time Attendance  

& Door Access

STEP 1 • 

Connection Points

STEP 2 • 

Connect AdapTec Plus to a Power Source

STEP 3 • 

Turn on the power to use the model for door access control 

only or for time attendance and door access control simultaneously.

Summary of Contents for AdapTec Plus

Page 1: ...Installer Guide ...

Page 2: ...ems A single AdapTec Plus can provide power simultaneously to a maximum 2 units of FingerTec terminals and 2 sets of door lock accessories such as EM Lock and drop bolt in one single system installation Prolonged Life Span of Hardware With data encryption the life span of the terminals could be prolonged without the risk of short circuiting when using AdapTec Plus Control IN OUT Terminals At An En...

Page 3: ...sive FingerTec DIY metal casing providing a cleaner installation SPECIFICATIONS MODEL AdapTec Plus PRODUCT DIMENSION L X W X H mm 198 x 45 X 131 WEIGHT 1 1 kg CPU 8 MHz 16 bit microprocessor POWER INPUT AC 110 240V universal input POWER OUTPUT DC12V 3A Supports up to 2 x FingerTec access control terminals 2 x electrical energized locks BACKUP POWER SYSTEM UPS or DC 12V rechargeable backup battery ...

Page 4: ...to be connected to power source with AC110 240V AC current will be supplied into this side and a DC 12V 3A current will be generated as output 2 These two cables V and V are default and are connected to the inner part of AdapTec Please do not remove or change these cables Access control power output module 1 These cables connect to a DC12V rechargeable backup battery During a power failure the bat...

Page 5: ...tact your local reseller or support fingertec com in case either LED is not lit up Door lock timer Users can adjust the timing for the EM Lock and Drop Bolt to close after opening using the door lock timer Turn the timer using a screwdriver turning clockwise will lengthen the time turning anti clockwise will shorten the time Note AdapTec Plus can be connected to other devices which have the same p...

Page 6: ...ol Power Output Module To Battery Tamper Siren EM Output Siren Door Wiegand Switch Output 12V Voltage Accept Exit Input Input 12V 0V GND WD0 WD1 Connection Points GND PWR WIRING DIAGRAMS AC900 FUNCTION Time Attendance Only STEP 1 Connection Points STEP 2 Connect AdapTec Plus to a Power Source STEP 3 Turn on the power to use FingerTec AC900 for time attendance only ...

Page 7: ... WD0 WD1 Connection Points GND PWR GND WD0 WD1 DC 12V Rechargeable Backup Battery Connection Points Release Button EM Lock Emergency 2 Break Glass NC 3 ON OFF C Key Switch NC D WIRING DIAGRAMS AC900 FUNCTION Access Control Only or Time Attendance Door Access STEP 1 Connection Points STEP 2 Connect AdapTec Plus to a Power Source STEP 3 Turn on the power to use FingerTec AC900 for door access con tr...

Page 8: ...Battery Tamper Siren EM Output Siren Door Wiegand Switch Output 12V Voltage Accept Exit Input Input 12V 0V GND WD0 WD1 Connection Points GND 12V WIRING DIAGRAMS R2 i Kiosk100 i Kiosk100 Plus Q2i Kadex and m Kadex FUNCTION Time Attendance Only STEP 1 Connection Points STEP 2 Connect AdapTec Plus to a Power Source STEP 3 Now you can turn on the power to use the system for time at tendance only ...

Page 9: ... Points GND 12V GND WD0 WD1 DC 12V Rechargeable Backup Battery Connection Points Release Button EM Lock Emergency 2 Break Glass NC 3 ON OFF C Key Switch NC D WIRING DIAGRAMS R2 i Kiosk100 i Kiosk100 Plus Q2i Kadex and m Kadex FUNCTION Access Control Only or Time Attendance Door Access STEP 1 Connection Points STEP 2 Connect AdapTec Plus to a Power Source STEP 3 Turn on the power to use the model f...

Page 10: ...ol Power Output Module To Battery Tamper Siren EM Output Siren Door Wiegand Switch Output 12V Voltage Accept Exit Input Input 12V 0V GND WD0 WD1 Connection Points GND 12V WIRING DIAGRAMS Face ID 2 FUNCTION Time Attendance Only STEP 1 Connection points STEP 2 Connect AdapTec Plus to a power source STEP 3 Turn on the power to use FingerTec Face ID 2 for time attend ance ...

Page 11: ...V GND WD0 WD1 DC 12V Rechargeable Backup Battery Connection Points WD0 WD1 SGND GND 12V Release Button EM Lock Emergency 2 Break Glass NC 3 ON OFF C Key Switch NC D WIRING DIAGRAMS Face ID 2 FUNCTION Access Control Only or Time Attendance Door Access STEP 1 Connection points STEP 2 Connect AdapTec Plus to a power source STEP 3 Turn on the power to use FingerTec Face ID 2 for door access control on...

Page 12: ...a preinstalled siren To use the siren feature we recommend you to install an additional alarm siren and connect it to the FingerTec terminals Benefits of using AdapTec plus with Alarm Siren We recommend you to install a terminal along with an AdapTec Plus if you plan to use the alarm siren In the AdapTec Plus an additional port is readily built to receive the alarm signal from the FingerTec termin...

Page 13: ... alarm siren and AdapTec Plus as below FUNCTION Face ID 2 i Kiosk 100 Q2i i Kiosk 100 Plus For Face ID 2 you will need to connect to alarm siren and AdapTec Plus as below Reminder to deactivate alarm siren 1 You can deactivate the alarm siren by pressing the push button that is connected to Siren Accept in the AdapTec Plus This action will turn off the alarm siren function in AdapTec plus However ...

Page 14: ...holes are for the screws and the bigger hole is for the network cable 2 Tighten the 4 screws to fix the Back Plate on the wall 3 Install the keyswitch as per instructions given in the box The keyswitch is an override key in case of a system failure or break down 1 Drill 3 holes on the wooden door 2 Place the Steel Bar on the door Insert the Silver Nut on one side and the Allen Key Screw on the oth...

Page 15: ...ut 1 1 2 3 4 feet 1 2 meter recommended CEILING INDOOR Emergency Break Glass Push Button 4 5 6 1 12V 3A DC Power Output 2 AdapTec Plus Note RefertoAdapTecuser guide for wiring diagrams 3 12V Rechargeable Bat tery Note It is recommended to place 1 2 and 3 out of sight either above a ceiling or wall mounted Emergency Break Glass and Push Button should be installed indoors These two items are for the...

Page 16: ...es are for the screws and the bigger hole is for the network cable 2 Tighten the 4 screws to fix the Back Plate on the wall 3 Install the keyswitch as per instructions given in the box The keyswitch is an override key in case of a system failure or breakdown 1 Lodge the U Bracket into the upper edge of the glass doorframe Tighten the 4 Allen Screws to hold the U Bracket into position 2 Place the S...

Page 17: ...C ON OFF Keyswitch To FingerTec Series 12V Rechargeable battery AC110 240V Power Input 4 5 6 1 12V 3A DC Power Output 2 AdapTec Plus Note Refer to AdapTec user guide for wiring diagrams 3 12V Rechargeable Battery Note It is recommended to place 1 2 and 3 out of sight either above a ceiling or wall mounted Emergency Break Glass and Push Button should be installed indoors These two items are for the...

Page 18: ...AdapTecTA Emergency Break Glass EM 600 EM 1200 Description Release Button Contactless Release Button Alarm Siren With Strobe Light 5V 12V Mini UPS Press EMERGENEGY DOOR RELEASE BREAK GLASS PRESS HERE EXIT ON OFF FINGERTEC EXCLUSIVE ACCESSORIES For more accessories go to accessory fingertec com ...

Page 19: ...orldwide Twitter FingerTec Worldwide To subscribe for FingerTec Newsletter www fingertec com subscribe R newsletter html Technical Tips and Latest user fingertec com Product Updates and Upgrades Email info fingertec com Sales support fingertec com Technical Register for Warranty www fingertec com GPW warranty htm FingerTec Accessory accessory fingertec com ...

Page 20: ...s with 2 screws Attach the L shape to the AdapTec Plus as shown and tighten the screws Open the cap look for the part shown in the diagram and you will see 2 holes www fingertec com 2011 FingerTec Worldwide Sdn Bhd All rights reserved Printed in Malaysia 102011 Install the piece to the AdapTec Plus The other 2 holes at the bottom Mount the AdapTec Plus on a wall Identify a location to mount the Ad...

Reviews: