Installation with 2 anchor point. 

 

 

 

 

 

Summary of Contents for MK1 NANO BUBBLER

Page 1: ...931 2240 E info finebubblewater com W www finebubbletechnologies com Director Founder Paul Botha Strictly Confidential Not to be copied without written consent by Fine Bubble Technologies Pty Ltd Cop...

Page 2: ...chnologies Pty Ltd Copyright 2018 All rights reserved 2 TABLE OF CONTENTS Introduction 3 Safety Terminology and Symbols 4 Instructions 4 Disposal of Packaging and Product 4 Warranty 4 Spare Parts 5 Tr...

Page 3: ...roper use of the product can cause personal injury and damage to property and may void the warranty Save this manual for future reference and keep it readily available at the location of the unit CAUT...

Page 4: ...ING A hazardous situation which if not avoided could result in death or serious injury CAUTION A hazardous situation which if not avoided could result in minor or moderate injury NOTICE A potential si...

Page 5: ...the product bears visible signs of damage 3 Unpack the unit follow applicable steps If the unit is packed in a carton then remove the staples and open the carton If the unit is packed in a wooden cra...

Page 6: ...tion Store the unit free from heat dirt and vibrations Rotate the Nano Bubbler shaft by hand several times at least every three months Treat bearings and machined surfaces so that they are well preser...

Page 7: ...rmful microbes and bacteria are positively charged As the minus and plus charge pull each other the ultra fine bubbles adhere to the microbes and the bacteria due to attractive force existing between...

Page 8: ...the Nano Bubbler Always remember to secure the safety rope used to lower the Nano Bubbler at the top on the edge of the floating buoy or other floating object used to fix the Nano Bubbler on the wate...

Page 9: ...ler turns on again automatically You must always try to eliminate the cause that triggered the intervention of the thermal protector impeller blocked due to for foreign objects in the Nano Bubbler coo...

Page 10: ...e animals or property To change the direction of rotation switch the two phases of the supply line DO NOT operate the machine in dry conditions Start the Nano Bubbler only when immersed in the liquid...

Page 11: ...ounder Paul Botha Strictly Confidential Not to be copied without written consent by Fine Bubble Technologies Pty Ltd Copyright 2018 All rights reserved 11 Installed How to install Installation Set 1 E...

Page 12: ...E info finebubblewater com W www finebubbletechnologies com Director Founder Paul Botha Strictly Confidential Not to be copied without written consent by Fine Bubble Technologies Pty Ltd Copyright 201...

Page 13: ...info finebubblewater com W www finebubbletechnologies com Director Founder Paul Botha Strictly Confidential Not to be copied without written consent by Fine Bubble Technologies Pty Ltd Copyright 2018...

Page 14: ...27 0 22 931 2240 E info finebubblewater com W www finebubbletechnologies com Director Founder Paul Botha Strictly Confidential Not to be copied without written consent by Fine Bubble Technologies Pty...

Page 15: ...h appropriate cable length is 2 5m For continuous operation in order to allow for proper cooling of the motor the motor must be completely immersed in the liquid minimum depth of immersion 300 mm To a...

Page 16: ...results MAINTENANCE ELECTRICAL HAZARD Disconnect and lock out electrical power before installing or servicing the unit WARNING Maintenance and service must be performed by skilled trained and qualifi...

Page 17: ...ty applications every month To fill the oil please see attached video For the motor driven Nano Bubbler to operate correctly is very important to use Food grade or similar types of oil In the case of...

Page 18: ...F Viscosity index D445 D445 105 547 12 0 68 142 744 14 6 78 225 1189 19 7 100 302 1603 23 8 118 424 2264 29 8 146 D2270 103 101 100 99 99 Flash Point COC o c O F D92 264 507 240 464 204 399 36 83 43 3...

Page 19: ...pied without written consent by Fine Bubble Technologies Pty Ltd Copyright 2018 All rights reserved 19 MK1 ULTRA FINE BUBBLE NANO BUBBLER Power Source 380V PH3 50Hz 240V PH1 50Hz 220V PH3 60Hz Output...

Page 20: ...2 931 2240 E info finebubblewater com W www finebubbletechnologies com Director Founder Paul Botha Strictly Confidential Not to be copied without written consent by Fine Bubble Technologies Pty Ltd Co...

Page 21: ...ca T 27 0 22 931 2240 E info finebubblewater com W www finebubbletechnologies com Director Founder Paul Botha Strictly Confidential Not to be copied without written consent by Fine Bubble Technologies...

Page 22: ...es com Director Founder Paul Botha Strictly Confidential Not to be copied without written consent by Fine Bubble Technologies Pty Ltd Copyright 2018 All rights reserved 22 Description 1 Electrical DB...

Page 23: ...rs 37kW to 7 5kW Larger motors of 11kW and above any Current Transformer with a 5 amp secondary can be used Eg 50 5 for 11kW and 18 5kW 80 5 or 100 5 for 22kW and 30kW etc In these instances pass LIVE...

Page 24: ...er 3 Booster Pump See enclosed installation booklet on installation of booster pump 4 Fibre Glass Vessel NOTICE Please read side of vessel to insure you do not exceed the maximum pressure Please insur...

Page 25: ...Founder Paul Botha Strictly Confidential Not to be copied without written consent by Fine Bubble Technologies Pty Ltd Copyright 2018 All rights reserved 25 8 Pressure Relief System See enclosed insta...

Page 26: ...a T 27 0 22 931 2240 E info finebubblewater com W www finebubbletechnologies com Director Founder Paul Botha Strictly Confidential Not to be copied without written consent by Fine Bubble Technologies...

Page 27: ...ct setting is used for MK1 See speck on MK1 for amps setting Motor direction wrong way 3 phases connected wrong on live connection Change the live connections around of 2 phases See diagram under 8 3...