DEFECT
CAUSE
SOLUTION
The mains fuses burn when the gene-
rator switch is pressed
Yellow LED 4 “THERMAL PRO-
TECTION” of fig. 1 lights up
Short circuit inside the generator
Contact FIMER technical assistance
Power supply cord too long
Supply power to the generator ccor-
ding to the instructions
When the torch button is pressed
the red “PILOT ARC” LED (2 of fig.
1) does not light up and the pilot
arc does not start
With the generator switch ON, the
machine does not turn on (the green
LED (3 of fig. 1) does not light up)
With the generator on, LED 3 shown
in figure 1 turns on and the machine
does not function
No mains voltage
Check the connection between the
machine and the mains power, and
the presence of voltage
Faulty generator
Contact FIMER technical assistance
Faulty torch (internal wires or button)
Disassemble the torch and check the
closing of the circuit between pins 1 and
9 of the plug with the button pressed.
Torch not screwed correctly in the
relative machine attachment
Install the torch correctly according
to the instructions
Torch not suitable for using with the
generator
Use recommended torches
10. TROUBLESHOOTING
Below are a list of some of the most common problems that may arise, with the relative solutions.
A power supply phase is missing
Check the power supply cord
and any external fuses
The mains voltage drops below during
the cutting process
Check the output of the mains line and
the power point where the machine is
connected
Intermittence factor too high
Reduce the intermittence factor
according to the instructions
Ambient temperature above 40°C
Use the generator according to the
instructions
Electric fan of the generator is broken
Air inlet for the ventilation is clogged
by dirt/generator is positioned in a way
to prevent ventilation
Remove dirt and position the generator
correctly according to the instructions
Contact FIMER technical assistance
When the torch button is pressed
the red “PILOT ARC” LED (2 of fig.
1) lights up but the pilot arc does
not start
Generator in protection mode
Find the active protection and follow
the instructions contained in this guide
Torch not screwed correctly in the
relative machine attachment
Assemble the torch correctly accor-
ding to the instructions
Impossible to adjust the cutting cur-
rent via knob 1 of fig. 1
External command connector is connected Disconnect the relative connector
Faulty generator
Contact FIMER technical assistance
Summary of Contents for TP 35K
Page 2: ......
Page 3: ...TP 35K TP 47KGEN ...
Page 4: ...TARGA DATI NOMINAL DATA LEISTUNGSCHILDER PLAQUE DONÉES PLACA DE CARACTERÌSTICAS ...
Page 16: ......
Page 28: ......
Page 40: ......
Page 42: ...2 SYMBOLES UTILISÉS ...
Page 52: ......
Page 54: ...2 SÌMBOLOS UTILIZADOS ...
Page 55: ...3 ...
Page 56: ...4 ...
Page 64: ...NOTE ...
Page 65: ...NOTE ...
Page 66: ...NOTE ...
Page 67: ......
Page 68: ......