background image

Page 3 

 

Assembly Procedure (ATVBK-3025-QR) 

Step 1 

Step 2 

Normally, the sprayer will be mounted on an ATV with the 

pump assembly at the operator’s back and the spray wand 

will  be  at  the  rear  of  the  unit.  Right  Hand  (RH)  and  Left 

Hand (LH) sides of the sprayer are determined as if you  

are standing behind the sprayer, looking at it (facing  

forward). 

 

 

A phillips head screwdriver is required for this step. 

 

(**)  Mount  tank  brackets  to  the  underside  of  the  tank  as 

shown  in  Step  1.  Use  (4)  flat  head  screws  to  secure  it  to 

the tank. The tank will rest on the surface of the brackets. 

Make sure the brackets are parallel with each other before 

tightening down the bolts. Do not over-tighten. 

Detail A 

After  your  tank  brackets  are  securely  attached,  turn  the 

tank assembly over and position it so that the cam handles 

which  extend  beyond  the  back  of  the  tank  are  facing  you 

and just hanging over the edge of the table or flat surface 

you are assembling this on. 

 

Secure  the  boom mounting  brackets  to  the  tank  mounting 

brackets with Cam handles as shown in Detail A. You can 

position them as needed within the slot on the bracket. Just 

be  sure  that  the  surfaces  of  both  brackets  are  even  with 

each other. 

 

You  are  now  ready  to  mount  this  unit  to  an  ATV,  using 

ratchet straps (NOT INCLUDED) 

Step 3 

Attach the boom to the boom mounting brackets with 

the (2)  u-bolts and (4) whiz locknuts. Make sure the u-

bolts are positioned within the grooves of the grommets 

on the boom tube 

 

NOTE: The purpose of these grommets is to pre-

vent metal-to-metal contact between the u-bolts, 

boom tube and boom mounting brackets. 

 

The grommets will ‘compress’ as you tighten the whiz 

locknuts onto the u-bolts. Tighten just so that the boom 

tube will NOT rotate within the grommets. Alternate the 

tightening of the locknuts to provide even pressure on 

the grommet. 

 

**DO NOT OVER TIGHTEN the whiz locknuts, as 

this may cause the boom tube to flatten slightly!

 

Summary of Contents for ATVBK-3025-QR

Page 1: ... CST If you should have a question or experience a problem with your Fimco Industries Product Visit our website www fimcoindustries com or call the Toll free number above Our technical support representatives will be happy to help you In most cases a customer service rep can resolve the problem over the phone To obtain prompt efficient service always remember to give the following information Corr...

Page 2: ... s carton ATVBK 3025 QR 5302334 Contents of Parts Bag 5278296 Contents of Bracket Kit 5278138 Wet Boom Sub Assembly 5275712 End Nozzle 5275122 Pkg of 2 5275713 Manifold Detail 5281541 See Page 7 for the Manifold Assembly Part Numbers ...

Page 3: ...you and just hanging over the edge of the table or flat surface you are assembling this on Secure the boom mounting brackets to the tank mounting brackets with Cam handles as shown in Detail A You can position them as needed within the slot on the bracket Just be sure that the surfaces of both brackets are even with each other You are now ready to mount this unit to an ATV using ratchet straps NOT...

Page 4: ...75122 Each click of the ratcheting motion is approx 15 This nozzle mounting stem Has a ratcheting motion For proper optimal spray coverage The nozzle must be at a 15 angle The 15 angle shown will prevent the outer Nozzles from overlapping with the center nozzle On Off Valve Positions Note The check valve diaphragm can fall out during transport if the knob is not turned to the ON or OFF position On...

Page 5: ...xture and water combination and start your spraying operation Adjust the pressure and spray as you did in the testing pro cedure Conditions of weather and terrain must be considered when setting the sprayer Do not spray on windy days Protective clothing must be worn in some cases Be sure to read the chemical label s before application Operation Fill the tank part way with water and then add the de...

Page 6: ...al object Even the slightest damage can change the flow rate and spray distribution Water rinse and dry the tips before storing WARNING Some chemicals will damage the pump valves if allowed to soak untreated for a length of time ALWAYS flush the pump as instructed after each use DO NOT allow chemicals to sit in the pump for extended times of idleness Follow the chemical manufacturer s instructions...

Page 7: ...Page 7 Exploded View Parts List ATVBK 3025 QR 5302334 End Nozzle Assembly 5275122 Center Nozzle Assembly 5275123 Boomless Wet Boom Assembly Exploded View Parts List 5275260 ...

Page 8: ...Warranty you must 1 provide written notice to Fimco Ind of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes necessary at the following address Fimco Ind 1000 Fimco Lane North Sioux City SD 57049 and 2 make the Equipment available to Fimco Ind or an authorized dealer within a reasonable period of time For more information about ...