![Fimap GENIE BS Use And Maintenance Manual Download Page 13](http://html1.mh-extra.com/html/fimap/genie-bs/genie-bs_use-and-maintenance-manual_2288978013.webp)
13
PREPARATION OF MACHINE
12. FIXING THE HANDLEBARS
For packaging purposes the handlebars are supplied folded; they must now be put in the working position. Proceed
as follows:
1.
raise the handlebars by pulling the lever - indicated by the arrow - upwards
2.
place the machine in the working position
3.
attach the recovery tank to the handlebars tube by means of the two hooks
4.
insert the tubes in the connectors that emerge from the recovery tank nut
13. SOLUTION
TANK
The recovery tank must be completely empty each time the solution tank is filled.
Verify that the cap is correctly inserted in its housing (1).
Verify that the quick connection is correctly connected (2).
14.DETERGENT SOLUTION
Proceed as follows each time the solution tank is filled:
1.
Make sure that the recovery tank is empty
2.
Make sure that the main switch is off
3.
Remove the inlet cap located on the right rear side of the machine.
4.
Fill it with clean water at a temperature not exceeding 50
C.
Add the liquid detergent to the tank in the concentration and manner indicated on the detergent manufacturer's label.
The formation of excess foam could damage the vacuum motor, so use only the minimum amount of detergent that is
necessary.
ATTENTION: Acid or alkaline maintenance products with pH values of between 4 and
10 may be used as detergents, provided they do not contain: oxidising agents, chlorine
or bromine, formaldehyde, mineral solvents.
ATTENTION: Always use detergents whose manufacturer's label indicates their
suitability for scrubbing machines. Do not use acid or alkaline products or solvents
without this indication.
always use low-foam detergent. To avoid the production of foam, put a minimum
quantity of antifoam liquid in the recovery tank before starting to clean. Do not use pure
acids.
1