Remove the suction pipe (11) from the suction nozzle (12) present in the collection shaft, press button
(13) to release the latch (Fig. 7) before pulling the suction pipe.
9.
Clean the inside of the suction pipe with a jet of compressed air, if necessary remove any obstructions.
10.
Unscrew the nozzle Stop Ring (14) (Fig. 8).
11.
Remove the Nebulizer nozzle (15) and clean it (Fig. 9).
12.
Refit the nebulizing nozzle (15) on the appliance and secure it using the nozzle stop ring (14).
13.
Clean the inside of the accessory suction chamber with a jet of compressed air, if necessary remove
any obstructions.
14.
Remove the detergent solution tank (16) from the support (Fig. 10), rinse the inside with a jet of water.
15.
Clean the suction filter (17) of the detergent solution (Fig. 11).
16.
Refit the whole.
TROUBLESHOOTING
This chapter shows the most recurring problems related to the use of the appliance. If you are unable
to solve the problems with the following information, please contact the service centre nearest to you.
PROBLEM
POSSIBLE CAUSE
SOLUTION
THE APPLIANCE
DOES NOT TURN ON
The main switch is not
activated.
Press the main switch.
The plug on the power cord
of the appliance, which is not
correctly connected to the
mains socket.
Connect the plug in the power
cord of the appliance to the
mains socket.
The electronic specifications
of the appliance do not
correspond with the electronic
specifications of the power
supply network.
Check whether the technical
data on the rating plate
correspond to the data of the
power supply.
The damaged power cord.
Contact a specialized
technician urgently.
The current line fuse is
damaged.
Replace the current line fuse.
THE APPLIANCE
DOES NOT SUCK THE
DETERGENT
The level of dirty liquid present
in the collection drum has
reached the critical level.
Empty the collecting drum.
The suction tube is clogged or
damaged.
Check the status of the suction
pipe
INSUFFICIENT
SUCTION
Suction hood not positioned
correctly.
Remove the suction hood and
reposition it correctly.
The lower suction hood gasket
does not adhere properly to the
collection drum.
Clean the lower suction hood
gasket and the upper edge of
the collecting drum.
The suction hose is not
correctly connected to the
nozzle in the collection drum.
Connect the suction pipe
correctly to the nozzle in the
collecting tank.
The suction tube is not
correctly connected to the
extension tube.
Connect the suction pipe
correctly to the extension tube.
The extension tube is not
correctly connected to the
suction accessory you are
using.
Collegare il tubo prolunga in
modo corretto all’accessorio
aspirante che si sta utilizzando.
There are impurities that
obstruct the suction circuit
(suction pipe, extension tube,
suction accessory).
Remove the impurities present
in the suction circuit
There are impurities that
obstruct the suction filters.
emove the impurities present in
the suction filters.
INSUFFICIENT WORK
Poor detergent leakage
Fill the detergent tank with
another cleaning solution.
Clean the nebulizer nozzle.
16
10
4
6
7
5
6
7
8
9
10
12
8
11
14
15
9
13
11
17
Summary of Contents for FE A65.2 DP
Page 2: ...ITALIANO 3 FRAN AIS 15 ENGLISH 25...
Page 37: ...37...
Page 38: ...38...
Page 39: ...39...