Filtration Group SFK-01 KG Translation Of The Original Instructions Download Page 9

 

Page 9 

 

Translation of the original instructions

 

Dust Removal Filter, Filtration Group GmbH, 25.01.18, Mat. No. 79340811, Version 12 

 

 

9.5 

Electrical connections 

 

DANGER!

 

 

Danger of electric shock! 

 Risk of serious or fatal injury in case of 

contact with electrical components. 

  All electrical installation work must be 

carried out by a suitably qualified 
electrician. 

 

 

WARNING! 

 

Explosion hazard! 

 Risk of injury to persons or damage to 

property 

  Connect a protective earth conductor. 

  Comply with the permissible ambient 

temperature. 

 

 

WARNING! 

 

Explosion hazard! 

 Risk of injury to persons or damage to 

property 

  Check the conductivity between all 

components! 

  Maximum permissible resistance:  

R < 10 

  Make sure that earthing is provided by 

the customer. 

 

 

9.5.1  2/2-way valve connection 

 
 

 

 
 

Fig. 11: 

Electrical connection of the 2/2-way valves 

 

9.6 

Cleaning control 

The cartridge is cleaned periodically. The pulse and interval 
times vary according to the process. The times indicated 
below are recommended standard values. 

 

t

p

 

Interval time 

Approx. 8 min 

t

i

 

Pulse time 

Approx. 0.3 s 

 

 

 

 
 

 

Fig. 12: 

Periodic cleaning 

 

 

 
 

 

10 

Start-up 

 

DANGER!

 

This FG dust removal filter is not allowed to be put into 
operation until it has been established that the 
machine/system in which it is to be installed complies 
with the requirements of the applicable EC directives, 
harmonised standards, European standards or equivalent 
national standards. 

 

 

WARNING! 

 

Explosion hazard! 

 Risk of injury to persons or damage to 

property 

  Check the conductivity between all 

components! 

  Maximum permissible resistance  

R < 10 

  Make sure that earthing is provided by 

the customer. 

 

10.1  Initial start-up or start-up after a prolonged 

shut-down 

  Inspect all system parts. 

  Remove all parts that do not belong to the system (such 

as tools, installation waste, etc.) 

  Check the pipe connections (e.g. clamps). 

  Tighten all screws and bolts. 

 

10.2  Starting up the dust removal filter 

CAUTION 

If the maximum permissible volumetric flow is 
exceeded 

 Risk of damage to the cartridges. 

  Be careful not to exceed the maximum permissible 

volumetric flow when the system is started up. 

 

  Turn on the compressed air supply. 

  Switch on the controller. 

  Start up the dusty system. 

  Throttle the volumetric flow if necessary. 

24 V DC 

230 V AC 

* Connect a protective earth 
conductor for use in hazardous 
areas 

 
 
 
 

Valve 

Time 

Summary of Contents for SFK-01 KG

Page 1: ...Translation of the original instructions Dust removal filter SFK 01 02 03 KG Material No of Instruction Manual 79340811...

Page 2: ...1 Inspection and maintenance schedule 11 14 2 Replacing the cartridges 12 15 Type number key 13 16 Cartridges used 15 17 Manufacturer s declaration 16 18 Declaration of conformity 17 19 Declaration of...

Page 3: ...re to be carried out Arrow Indicates responses to actions 3 Glossary System Customer s complete plant in which the FG dust removal filter is integrated Pressure difference differential pressure Pressu...

Page 4: ...ty 5 Intended application DANGER PROHIBITED Use for purposes other than that described below without prior consultation with the manufacturer Use in hazardous areas unless explicitly mentioned in the...

Page 5: ...2 The dust particles are separated on the cartridges 3 The cleaned gas enters the cleaned gas chamber Fig 2 Filtration principle 4 The cartridge is cleaned periodically by means of a pulsed jet of com...

Page 6: ...ation offer order confirmation and or the cartridge data sheet for more technical data 7 2 Compressed air connection Compressed air 6 7 bar dewatered Consumption per cleaning cycle Approx 10 lN 7 3 No...

Page 7: ...system is only allowed to be installed accepted and tested by a suitably qualified person 99 98 EC WARNING If the system is installed by unauthorised persons Risk of injury All warranty claims are ren...

Page 8: ...ample of a pressure relief device 9 3 Pipe connections CAUTION Stress relief must be provided for all pipe connections to the dust removal filter Avoid pipe bends or contractions immediately upstream...

Page 9: ...g 12 Periodic cleaning 10 Start up DANGER This FG dust removal filter is not allowed to be put into operation until it has been established that the machine system in which it is to be installed compl...

Page 10: ...he fan or shut down the dusty system Turn off the compressed air supply 12 2 Prolonged shut down 48 h Start a manual cleaning cycle Switch off the fan or shut down the dusty system Turn off the compre...

Page 11: ...emoval filter system again Observe the dust removal filter system Does it operate normally If the filter system does not operate normally refer to the troubleshooting table section 13 14 1 Inspection...

Page 12: ...dvertently switched on again Wear personal protective equipment After approximately 5 minutes time required for the dust to settle bang hard on the maintenance door so that any accumulated dust drops...

Page 13: ...arts S1 Standard type with bucket S2 Standard type with bag S3 Standard type with drawer S5 Bag dumping unit S6 Product separator with cone S7 Product separator with prepared cone S Standard type with...

Page 14: ...artridge types Horizontal Untreated gas side 51 852 902 300 852 838 Horizontal Untreated gas side RD 72x5 52 852 903 600 Horizontal Untreated gas side RD 72x5 53 852 904 1000 Horizontal Untreated gas...

Page 15: ...ata in the table refer to the contract documentation offer order confirmation No Qty Designation FG Mat No Material 1 2 3 4 Changed cartridges Date Changed by No Qty Designation FG Mat No Material 1 2...

Page 16: ...Page 16 Translation of the original instructions Dust Removal Filter Filtration Group GmbH 25 01 18 Mat No 79340811 Version 12 17 Manufacturer s declaration...

Page 17: ...Page 17 Translation of the original instructions Dust Removal Filter Filtration Group GmbH 25 01 18 Mat No 79340811 Version 12 18 Declaration of conformity...

Page 18: ...Page 18 Translation of the original instructions Dust Removal Filter Filtration Group GmbH 25 01 18 Mat No 79340811 Version 12 19 Declaration of incorporation As defined by the EC Machinery Directive...

Page 19: ...Page 19 Translation of the original instructions Dust Removal Filter Filtration Group GmbH 25 01 18 Mat No 79340811 Version 12...

Page 20: ...Page 20 Translation of the original instructions Dust Removal Filter Filtration Group GmbH 25 01 18 Mat No 79340811 Version 12...

Page 21: ...Page 21 Translation of the original instructions Dust Removal Filter Filtration Group GmbH 25 01 18 Mat No 79340811 Version 12...

Page 22: ...tract documentation 4 D Dew point 3 Direction of rotation 10 Dirty gas chamber 5 Dust bucket 11 E Environmental protection 3 F Fan 10 Filter elements 12 Filter plate 10 Final surge 3 L Leakage 2 M Mai...

Page 23: ...Filtration Group GmbH Schleifbachweg 45 D 74613 hringen Phone 49 7941 6466 0 Fax 49 7941 6466 429 fm de sales filtrationgroup com www filtrationgroup com 79340811 I12 01 2018...