Dust Removal Filter, Filtration Group GmbH, 25.01.18, Mat. No. 79340811, Version 12
14
Maintenance
DANGER!
Explosion hazard!
⇒
Risk of injury to persons or damage to
property
•
Work is only allowed to be carried out in
hazardous areas if appropriate safety
precautions are implemented.
•
Safety precautions must be implemented
by the owner.
WARNING!
If the system is maintained by unauthorised
persons
⇒
Risk of injury
⇒
All warranty claims are rendered invalid
•
The system must be maintained by a suitably trained
person!
Before all maintenance work:
•
Shut down the dust removal filter/system.
•
Clean the cartridges in a rapid cleaning cycle.
•
Turn off the compressed air supply.
•
Decompress the pressure vessel (e.g. by starting a
manual cleaning cycle).
•
Take steps to prevent the machine/system from being
switched on again by unauthorised persons.
•
Wear protective clothing and equipment appropriate to
the hazard potential of the medium (e.g. goggles,
respirator, protective clothing, etc.).
•
Carry out the maintenance work.
•
Start up the dust removal filter/system again.
•
Observe the dust removal filter/system.
Does it operate normally?
•
If the filter/system does not operate normally, refer to the
troubleshooting table (section 13).
14.1 Inspection and maintenance schedule
Refer also to the contract documentation.
Interval
Component
Activity
Weekly
Dust removal filter
Carry out a visual
inspection of the
exterior
Compressed-air
maintenance unit
Carry out a visual
inspection of the
water separator and
drain if necessary
Dust bucket/bag
Carry out a visual
inspection and empty
if necessary
Monthly
Cartridges
Check the assembly
torque (> 6 Nm)
Carry out a visual
inspection for cracks
Clamping bands
Carry out a visual
inspection for
corrosion
Bolted clamping
bands
Carry out a visual
inspection for
corrosion
Bolted flanges
Carry out a visual
inspection for
corrosion
Dust removal filter
Check the
conductivity between
all components.
Note the maximum
permissible
resistance: R < 10
Ω
Yearly
Compressed air
connections
Check
Cartridges
Check the
conductivity between
all components.
Note the maximum
permissible
resistance: R < 10
Ω
The necessary maintenance work is
dependent on the particular application.
Please consult the manufacturer if necessary.
1
Check more frequently if large amounts of dust
accumulate.