Installation
WARNING!
Explosion hazard!
⇒
Risk of injury to persons or damage to
property
•
This FG dust removal filter is only allowed
to be installed and operated in the category
specified in the contract documentation
(offer/order confirmation).
•
If no category is specified: Do not operate
the FG dust removal filter in hazardous
areas!
•
The owner is responsible for zoning.
•
The owner of the plant is solely responsible
for implementing the appropriate explosion
protection measures!
•
If in doubt, please consult the responsible
authorities.
WARNING!
Explosion hazard!
⇒
Risk of injury to persons or damage to
property
•
The system is only allowed to be installed,
accepted and tested by a suitably qualified
person (99/98/EC).
WARNING!
If the system is installed by unauthorised
persons
⇒
Risk of injury
⇒
All warranty claims are rendered invalid
•
The system must be installed by a suitably trained
person!
WARNING!
Danger when pressure is vented
⇒
Risk of injury
•
Keep well away from the pressure vent area.
•
Heed the manufacturer’s instructions.
9.1
Installation
WARNING!
Explosion hazard!
⇒
Risk of injury to persons or damage to
property
•
Check the conductivity between all
components!
•
Note the maximum permissible resistance:
R < 10
Ω
.
•
Make sure that earthing is provided by the
customer.
It must be possible to remove the filter
insert in order to carry out maintenance
work.
•
The unit must be installed on a firm surface.
Fig. 6:
Installation with clamp ring
Fig. 7:
Installation with flange ring
H
Top part Flange seal
Clamp ring
Nozzle (optional)
Top part Seal
Flange ring