9.2 Pressure relief
Design measures must be incorporated on the clean side
to prevent inadmissible excess pressure on the dirty side
as well as reverse flows.
Install pressure relief devices and / or check valves if
necessary.
Fig. 7: Mechanical installation
9.3 Installation
•
Vent the coalescer housing before starting up the unit.
To do this, loosen the vent screw on the housing cover,
then close it again as soon as liquid starts to exit.
10 Start-up
DANGER!
This coalescer is not allowed to be put into operation until
the relevant machinery into which it is to be incorporated
has been declared in conformity with the applicable EC
directives, harmonised standards, European standards or
equivalent national standards.
•
Only approved hydraulic fluids may be
filtered (refer to section 5).
•
The coalescer must not be started up if it
exhibits visible damage.
Make sure the protection caps have been removed from
the connections.
Make sure there are no open connections into the
atmosphere.
Start up the unit.
Open the vent screw carefully until liquid exits from it.
Recover any leaking fluids in a suitable vessel.
Check that all pipe connections are tight.
Tighten all screws.
11 Normal operation
IMPORTANT!
Danger if the unit is operated incorrectly!
Risk of damage to property.
•
Prefiltration is recommended.
Please always ensure that you have a
sufficient quantity of original FG replacement
elements in stock. Disposable elements
cannot be cleaned.
The coalescer is used to separate water from hydraulic
fluids / diesel / marine diesel oil.
The separated water collects in a special reservoir and
must be drained off as soon as the water level sensor
trips.
If the coalescer element is dirty, the red button of the
maintenance indicator on the cover of the coalescer
housing jumps out and an electrical signal appears.
The optimum working range is a ∆p of 0.4 ± 0.2 bar.
Water drain
•
The water must be disposed of in a manner
which does not pollute the environment.
•
Place a suitably sized collection vessel underneath the
water drain.
•
Open the water drain if the MAX signal is present.
•
Close the water drain if the MIN signal is present.
12 Maintenance
CAUTION!
Danger if unauthorised work is carried out on
the unit!
Risk of injury.
•
All maintenance work must be carried out by a suitably
trained person.
Always use FG original filter elements.
Dismantling
clearance
Drain
At least 80 mm for outgoing
cables of water level sensors
and possibly more for piping
Summary of Contents for PiW 2175
Page 2: ......
Page 3: ...Originalbetriebsanleitung PiW 2175 Mat Nr der Betriebsanleitung 72348069...
Page 21: ...Translation of the original instructions PiW 2175 Mat No of original instructions 72348069...
Page 40: ......
Page 41: ...Traduction du mode d emploi original PiW 2175 N d identification du mode d emploi 72348069...