Page 6
Translation of the original instructions PiW 2175, Filtration Group GmbH, 28.06.20, Mat. No. 72348069, Version 04
7
Technical data
7.1 Order-specific data
The order-specific data can be taken from the name-plate.
7.2 Technical data of the PiW 2175
Flow rate
Max. 50 l/min
Filter rating
7 µm
Fluid temperature range
+5°C to +90°C
Fluid temperature range
(marine version)
+5°C to +70°C
Ambient temperature
0°C to 90°C
Temperature range
+5 to +90°C
Max. delivery pressure
16 bar
Viscosity range
3 to 100 mm²/s
Seal material
NBR
Weight
65 kg
Dimensions (L x W x H)
730 x 360 x 360 mm
Water drain
G ¼"
Maintenance indicator
2.2 bar differential pressure
Water flow rate switching
point
Approx. 2 l until upper water
level sensor shows a value
Input
G 2"
Output
G 1.5"
7.3 Technical data of the maintenance indicator
Switching voltage
250 V AC / 200 V DC
Switching current
1 A
Switching power
70 W
Fig. 6: Circuit diagram PiS 3092
7.4 Technical data of the water level sensors
Refer to section 14
8
Transport and storage
Transport
•
Always transport in the original packaging.
•
Avoid vibration.
Storage
•
Always store in the original packaging.
•
Always store in a dry, frost-free room.
Seaworthy packaging is specified in the
contract documentation as an option.
9
Installation
DANGER!
Danger if unauthorised work is carried
out on the unit!
Risk of injury to persons or damage to
property.
•
The unit is only allowed to be installed,
accepted and tested by a suitably trained
person (99/98/EC).
WARNING!
Danger if unauthorised work is carried out on
the unit!
Risk of injury to persons or damage to property.
•
All installation work must be carried out by a suitably
trained person.
9.1 Installation
It must be possible to remove the coalescer
element in order to carry out maintenance
work.
Use only suitable, chemically resistant seals
for the piping.
•
Make sure the protection caps have been removed from
the connections.
•
Prepare a suitable location for installing the unit
(e.g. a trough).
•
Be sure to allow the required clearances for dismantling
and discharging (see drawing).
•
Install the coalescer vertically.
•
Fasten the coalescer to the mounting pads.
•
Connect the pipes to the coalescer without stress.
•
Connect the water drain and adjust it using an external
shut-off device.
•
Make sure the water level sensors are connected
correctly.