![Filtration Group Pi 210 Series Manual Download Page 42](http://html1.mh-extra.com/html/filtration-group/pi-210-series/pi-210-series_manual_2288863042.webp)
Duplex Filter Pi 2110 NG 630+1000
6
10. Installation, operating and maintenance instructions
10.1 Filter installation
When installing the filter make sure that sufficient space is available
to remove filter element and filter housing.
The maintenance indicator must be visible.
-
10.2 Connecting the electrical maintenance indicator
The electrical indicator is connected via a 2-pole appliance plug ac-
cording to DlN EN 175301-803 with poles marked 1 and 2. The elec-
trical section can be inverted to change from normally open to nor-
mally closed position or vice versa.
-
10.3 When should the filter element be replaced?
1 .
Filters equipped with visual and electrical maintenance indicat-
or:
During cold starts, the indicator may give a warning signal.
Press the red button of the visual indicator once again only after
operating temperature has been reached. If the red button im-
mediately pops up again and/or the electrical signal has not
switched off after reaching operating temperature the filter ele-
ment must be replaced after the end of the shift.
2 .
Filters without maintenance indicator:
The filter element should be replaced after the trial run or flush-
ing of the system. Afterwards follow instructions of the manu-
facturer.
3 .
Please always ensure that you have original Filtration Group
spare elements in stock: disposable elements (Sm-x) cannot be
cleaned.
10.4 Element replacement
Note: The maintenance indicator monitors the filter side in operation,
which is identified by the position of the switching lever catch. The
change-over transfer valve must be switched prior filter servicing.
Now the signal of the maintenance indicators cancelled and the red
button can be repressed again.
1 .
Operate and hold pressure equalizing lever located behind
switching lever. Pull catch knob and swivel switching lever.
Place through or drip pan underneath to collect leaving oil.
Close pressure equalization valve.
2 .
Loosen vent screw of the filter side not in use by 2-3 turns; max.
until contact is made with the safety stop.
3 .
Remove drain plug in housing bottom and drain oil.
4 .
Unscrew filter cover counter-clockwise.
5 .
Lift out filter element.
6 .
Check seal on filter cover. We recommend replacement in any
case.
7 .
Make sure that the order number on the spare element corres-
ponds to the order number of the filter name-plate. To ensure
no contamination occurs during the exchange of the element
first open the plastic bag and push the element over the spigot
in the filter head. Now remove plastic bag.
8 .
Push the element carefully over the spigot and tight cover until
full stop. Back off the cover 1/8 turn.
9 .
Tighten drain plug housing bottom.
10 . To refill the filter chamber, operate only the pressure equaliz-
ing lever, until fluid emerges bubble-free from the drain cavity.
11 . Tight vent screw. Check for leckage by actuating the equaliz-
ing lever again.
11. Spare parts list
Order numbers for spare parts
Position
Type
Order number
Seal kit for housing
NBR
70318468
FPM
70318469
EPDM
70318471
Maintenance indicator
Visual PiS 3098/2,2
77669971
Visual/electrical PiS 3097/2,2
77669948
Electrical upper section only
77536550
Seal kit for maintenance indicator
NBR
77760309
FPM
77760317
EPDM
77760325