Translation of the original instructions MFS-05
Δp, Filtration Group GmbH, 16.01.18, Mat. No. 70303409, Version 03
19
Appendix: Default settings
19.1 Main parameters of the MFS-
05 Δp in “interval time control” mode
Parameter
Comments
Factory setting
Operation
No. of valves
Refer to section 6 for information about settings
N
Interval potentiometer
Controller characteristic, section 10.9
60
Pulse time
Pressure cleaning
Rotating wing
0.1 s
1.5 s
Post-cleaning cycles
0
Alarm threshold
18 mbar
Terminal assignment
See circuit diagram
Jumper 18-19
Jumper settings
Schw./Reg. jumper
Up
T/G Cycle jumper
Up
19.2 Other operating modes
19.2.1 “Switching threshold” mode
Parameter
Comments
Factory setting
Operation
Jumper settings
Schw./Reg. jumper
Down
T/G Cycle jumper
Up
High threshold
14 mbar
Cleaning cycles
1
Terminal assignment
See circuit diagram
Jumper 18-19
Jumper settings
Schw./Reg. jumper
Down
T/G Cycle jumper
Up
19.2.2 “Time control” mode
Parameter
Comments
Factory setting
Operation
Terminal assignment
Terminals 16-17 and 18-19 jumpered
Interval time
600 divided by the number of valves n
xx
Jumper settings
Schw./Reg. jumper
Down
T/G Cycle jumper
Up