Appendix: Set of instrument lines and protective filter (ID No. 78341984)
To measure the differential pressure:
•
Connect the sensor to the measuring points upstream and downstream of the filter plate using the instrument lines.
•
The instrument lines should be protected and laid without any kinks.
•
No condensate must be allowed to accumulate on the instrument lines. Provide a condensate trap if necessary.
•
No dust protection is necessary for the cleaned gas line.
Leaking or dirty lines can lead to measurement errors and malfunctions.
Fig. 23: Installation drawing and spare parts
Elbow bulkhead screw
fitting for hose
OD 6 mm
77974413
Instrument line
Hose PU/4 black
78238248
Screw-on connection
G 1/4“
77940166
Sealing ring PVDF
76141188
Filter plate
Hole
∅
13.5 mm
Casing
Hole 2 x Ø14 mm
Nipple G 1/4"
78342024
Membrane filter Ti 56
Bottom side coated
78342032
Snap ring
15x1 DIN 472 1.4310
77749500
+
-