Chapter 2: Troubleshooting Procedures
Industrial Dynamics Company, Ltd. ©
Form 42600 (10/03)
2-29
Faulty Bottles Detected But Not Rejected
1. Check for and correct any maintenance related or bottle handling
problems as discussed earlier in this chapter.
Check
DIAGNOSTICS > DSP BOARDS
screen. Look for possible
causes and solutions as follows:
SYMPTOM
CHECK
SOLUTION
Rejector
Air pressure.
Set to 310 - 414 kPa (45 - 60 PSI).
Solenoid Valve not activating.
Replace the Solenoid.
Plugged pressure lines/parts.
Press button on Solenoid valve
several times while starwheel is
rotated to clear pipes and ports.
If not cleared, check the piping for
blockage.
Reject Signal
Check reject signal flow.
Replace faulty components/parts.
Wiring.
Repair loose or broken wiring.
Bottle Handling
Check bottle handling at reject
point.
Replace/adjust parts as necessary.
Encoder
Check starwheel "Home"
position.
Replace encoder or associated parts.
Repair wiring if necessary.