Excessively worn or damaged guide rails may cause bottle handling
problems inside the OSW tunnel.
NOTE
Removing any bottles immediately in front of the OSW System or
anywhere between the OSW unit and the main Omnivision during
production may cause bottle handling problems and false or missed
rejects.
To troubleshoot the bottle handling problems on the main Omnivision
unit, proceed as follows:
1. Go to the
CONTAINER SETUP > BOTTLE CHANGEOVER
screen.
2. Select the correct bottle type by pressing the button which displays
the present bottle. Verify the Dash Numbers on the middle of the
screen.
3. Verify that:
a.
the correct bottle type has been selected
b. the correct bottle guide assemblies, deadplate, starwheel and
spacers (if any) have been installed
c.
the Inspection Head height is adjusted to the correct position
4. Proceed with troubleshooting various bottle handling problems as
explained in the following sections.