Testing CB4 Circuit.
1.
Remove connector if OSW option is included PL1-J5 (TO OSW
DC POWER).
2.
Turn CB4 ON.
3.
Verify that the voltage at PL1-J5 is 120VAC.
4.
Turn CB4 OFF and reconnect the connector PL-P5.
Testing CB5 Circuit.
1.
Disconnect MTR3-P1 (Diffuser Drive Motor)
2.
Turn CB5 ON
3.
Verify that the voltage at MTR3-P1 is 120VAC
4.
Turn CB5 OFF.
Testing CB6 Circuit.
1.
Turn CB6 ON.
2.
Verify that the voltage at PL1-J1 and Fan3-P1 is 120VAC.
3.
Turn CB6 OFF.
Testing CB7 Circuit.
1.
Disconnect XFMR4-P1 (Base Strobe Transformer)
2.
Turn CB7 ON.
3.
Verify that the voltage at XFMR4-P1 is 120VAC.
4.
Turn CB7 OFF.
Testing CB8 Circuit.
1.
Remove the following connector:
• XFMR3-P1 (Finish Strobe XFMR)
2.
Turn CB8 ON.
Summary of Contents for Omnivision 1000 Series