background image

Operating instructions

1.

Specification

1.1  Intended use

The vibrating level indicator are to be used to control the maximum 
or minimum level of bulk solids in silos or vessels.

It is recommended for dusty and powdery, granulated and grainy 
bulk goods like dust, flour, grain, sand, plastic, etc. 

1.2

Function

The probe must to be exposed to the material. The probe of these 
controllers is activated to its resonant frequency by a piezoelectric 
system. When the product covers the probe, the vibration is 
dampened and the control unit reverses the signal.
When the product disappears from the fork, it returns to the normal 
vibrating state and the signal turns to the initial position.

1.3

Technical data

Manufacturer

Talleres Filsa, S.A.U.

Address

Bernat Metge, 33
08100 Mollet del Vallès
(Barcelona)

Name

Vibrating level indicator

Type

ILV-120

ref:

 2190-0-200

ILV-120 Sens.

ref:

 2190-S-200

ILV-130

ref:

 2190-0-300

ILV-130 Sens.

ref:

 2190-S-300

ILV-150

ref:

 2190-0-500

ILV-150 Sens.

ref:

 2190-S-500

Sypply voltage

20  ... 250 V AC/DC

3 VA

Density of the product

3

From 0.02 t/m

3

From 0.01 t/m

Maximum pressure

+10 bar

Cable entry

2 of M20x1.5

Detecting level

1 s

Starting vibrating

2  ...  5 s

ILV-120

ILV-130

Under request up to

ILV-150

with a minimum 

bulk density from 0.01 t/m and a maximum grain size of 40 mm.

It is not recommended for sticky solids or products that have the 
tendency to settle over the probe.

Response time

Product temperature

 and 

-40 °C  ...  +80 °C

(

 +150 ºC)

-40 °C  ...  +70 °C

Ambient temperature

Power consumption

Standard models

Sensitive models

-40 °C  ...  +60 °C

 

Relay output

2x (1 NO + 1 NC)  

8 A / 250 V AC, 1.5 A / 48 V AC

8 A / 24 V DC

Function status

Relay enabled: red LED

Resonance frecuency

285 Hz

Protection

IP66 according DIN EN60529

IP67 according DIN EN60529

200 kg

Housing

Probe

Horizontal

Vertical

Weight

1.70 kg depending on the model

Max. load upon the probe

150 N

1.000 N

Max. cable load ILV-150 

1.4

Materials

Housing

Aluminium

Probe

Stainless Steel 1.4301

Cable

Double insulation Polyuretane and 
shielded cable

1.5

Dimensions

Approximate measures are given in mm. 

ILV-120

ILV-120, ILV-130 

 ILV-150

and

Talleres Filsa, S.A.U. 

 www.filsa.es   

 E-08100 Mollet del Vallès (Barcelona)   Tel. +34 93 570 46 01   Fax +34  93 570 24 71   [email protected] 

03

07/14 © by FILSA  

MI-ILV12035-EN-03

1 " 1/2 tappered
DIN 2999 

50

129

114

65

48

157

172

29

16

2 of M20x1.5

ILV12035-001