background image

Detection adjustment

 selector inside the housing, it can be selected the 

function of the device depending on the position of the selector.

FH - High level. For high level detection, the relay is disengaged 
when the probe is covered of product. Red LED flashing. 
FL - Low level. For low level detection, the relay is disengaged 
when the probe is uncovered of product. Red LED flashing. 
The Red LED is switched off if there is no supply. 

Sensitivity adjustment

The vibrating controller ILV-120 has a regulation system that 
allows the adjusment of the sensitivity. The device is adjusted at 
the medium sensitivity to detect the majority of materials. To 
change the sensitivity, change the position of the bridge selector:

3

A - light and low density materials, density of product up to 50 t/m .
B - standard adjustment, for the majority of the materials
C - heavy materials with high density. Light materials can not be 
detected with this adjustment.

- Fasten the cable gland after making the electrical connection.

- Fix and fasten the screw nut of the cable gland to make sure of 

the water-tightness.

- The cable glands must be always be facing downwards to 

prevent the ingress of humidity into the housing. If the housing is 
not in the right position:

1- Remove the housing cap.

2- Loosen the position screw half a turn, located at the centre..

3- Turn the case to the right or the left (never a complete turn)until 

the cable glands are facing downwards.

4- Tighten the position screw and refit the cap.

With the bridge

To select the type of detection, change the position of the bridge 
selector with: 

Cable gland

3.

Use

3.1

Commissioning

- Put the controller into operation only if the installation and the 

electrical connection have been done correctly.

3.2

Normal operation

- Use the controller in its intended application only. 

- Comply with the specifications 

- If the controller is damaged, disconnect it immediately.

- It is forbidden to make changes to the device. This violates the 

Normative. 

3.3

Inexpert handling

- Ignoring the Safety instructions and the Operating instructions.

- Not intended use.

- Making changes or handling the controller.

- Violation against applicable Law and Standards.

- Using of non original parts.

4. 

Maintenance, servicing and spare parts

4.1

Maintenance

- If used correctly, no specific maintenance is required.

4.2

Servicing

- Check and review the state of the housing, the probe and the 

correct commutation of the electrical contacts, as well. 

4.3

Spare parts

- Use original spare parts.

- The spare part for these controllers are the probe, the housing 

and the printed circuit board.

5.

Storage

- Store the controller in a dry and dust-free environment.

6.

Disposal

- The controller can be recycled.

- The disposal applies to the valid environmental Guidelines 

according to the location of the carrier and the local 
manufacturing conditions.

on the data plate and the technical 

data of this manual.

Switch off the power supply, before disconnecting the device.

ILV-120, ILV-130 

 ILV-150

and

Talleres Filsa, S.A.U. 

 www.filsa.es   

 E-08100 Mollet del Vallès (Barcelona)   Tel. +34 93 570 46 01   Fax +34  93 570 24 71   [email protected] 

05

07/14 © by FILSA  

MI-ILV12035-EN-05

FL

FH

A

B

C

ILV12035-006

Sensitivity bridge selector

Detection type bridge selector

FILSA constantly strives to improve its products and reserves the right to modify designs, materials and data without prior notice.

Keep this manual for further questions!

Reviews: