7.  SERVICE LIFE AND FUNCTIONAL TEST

It is recommended to replace smoke detectors 5 years after the production date. You can find this date on the device. 

The fifthplay smoke detector tests its battery capacity every 2 hours. If the capacity is less than 2.7V (+/-0.1V), a 
message is sent via the app and a visual and audible signal can be observed on the smoke detector itself (also see (5) 
Alarm signals and Visual Indication). 

Test the smoke detector on a weekly basis by holding down the test button until the alarm sounds (hold down for 
approximately 4 seconds). If the smoke detector is functioning properly, you will hear 3 beeps and the red LED lamp 
will flash fast and continuously. 
If the smoke detector only beeps once and the red LED lamp flashes only 3 times, the smoke detector is not functioning 
properly. If this is the case, it must be checked. 

8.  FEDERAL COMMUNICATIONS COMMISSION STATEMENT

This product complies with all of the relevant European guidelines and regulations. If applicable, 
you can find the EC declaration of conformity regarding this product at 

http://cube.fifthplay.

com/downloads.

This product cannot be deposited in the unsorted waste. Take your discarded product to a 
recycling centre or a recognised collection point. Just like producers and importers, you too 
play an important role in the promotion of sorting, recycling and reuse of waste electrical and 
electronic equipment. To finance the rubbish collection and waste treatment, the government 
levies recycling charges in certain cases (included in the price of this product).

9.  LIMITED PRODUCT WARRANTY

 

The warranty period is two years from the date of delivery. The delivery date is the invoice date of purchase 
of the product by the consumer. If there is no invoice, the date of production applies.

 

The consumer is obliged to inform fifthplay in writing about the non-conformity, within two months of 
noticing the defect.

 

In case of a non-conformity, the consumer only has the right to a product repair or replacement free of 
charge, which shall be decided by fifthplay.

 

fifthplay shall not be held liable for a defect or damage resulting from incorrect installation, improper or 
careless use, incorrect operation, transformation of the product, maintenance that does not adhere to the 
maintenance instructions or an external cause, such as damage due to moisture or overvoltage.

 

The compulsory regulations of the national legislation concerning the sale of consumer goods and the 
protection of the consumer in the countries where fifthplay sells, directly or via sister companies, subsidiaries, 
chain stores, distributors, agents or permanent sales representatives, take priority over the above-mentioned 
rules and regulations.

Summary of Contents for 98-401

Page 1: ...OR THE SMOKE DETECTORS 4 5 INSTALLATION AND ACTIVATION 5 6 ALARM SIGNALS AND VISUAL INDICATION 9 7 SERVICE LIFE AND FUNCTIONAL TEST 10 8 FEDERAL COMMUNICATIONS COMMISSION STATEMENT 10 9 LIMITED PRODUC...

Page 2: ...ork Each device driven by Z wave functions as a signal amplifier so that multiple devices ensure a greater number of transition routes which help to eliminate RF dead spots Z Wave devices with the Z W...

Page 3: ...CONTROL PARAMETERS Temperature 0 49 C Relative humidity 10 95 Action radius 30 m CURRENT STANDARD EN14604 2005 1172 CPR 150476 01 Z WAVE COMMAND CLASSES COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLA...

Page 4: ...n the ceiling is not possible mount the smoke detector on the wall at approximately 10 to 15 cm from the ceiling DON T Rooms in which strong water damp dust or smoke arise under normal conditions Clos...

Page 5: ...ctor by turning in a counter clockwise motion 2 Open the cover of the battery B place the battery and close the cover again 3 Place back the rear side of the smoke detector by turning in a clockwise m...

Page 6: ...nfirmation message on your screen Please note If no device is found within 30 seconds press the programming button A again 9 Once the smoke detector has been added you will see a notification on your...

Page 7: ...ation of the plugs and screws 3 Use a 5 mm drill and drill 2 holes on the marked locations 4 Place the plugs in the drill holes and secure the rear side A of the smoke detector in place by using the s...

Page 8: ...tion mode will automatically be terminated after 2 minutes 7 Press 3x briefly less than 1 second on the program switch of the sensor C to disconnect it from the gateway 8 Once the smoke detector has b...

Page 9: ...perly Red LED flashes once every 334 seconds LOW BATTERY VOLTAGE Red and orange LED flash continuously 1 beep every 43 seconds Push notification text message email DISMANTLING SECURITY the smoke detec...

Page 10: ...ike producers and importers you too play an important role in the promotion of sorting recycling and reuse of waste electrical and electronic equipment To finance the rubbish collection and waste trea...

Page 11: ...ur frequently asked questions page on cube fifthplay com FAQ or consult the user manuals on cube fifthplay com downloads 11 CONTACT Email hello fifthplay com Telephone 32 0 3 808 70 38 12 DISTRIBUTOR...

Reviews: