5.1.2  CONNECTING A SMOKE DETECTOR TO YOUR FIFTHPLAY CUBE

C

 

 IMPORTANT: Ensure that the smoke detector is in the immediate vicinity (0.5 to 1 meter) of the gateway. 

You can connect your smoke detector to your fifthplay cube in the following 2 ways:

Via the APP:
1. 

Open the fifthplay Home app and log in.

2. 

At the top left of the app, click on   and select '

CONFIGURATION

'.

3. 

Go to '

DEVICES

'.

4. 

At the top right, click on 

+

.

5. 

Select '

SENSOR

' as the type of device.

6. 

Select '

SMOKE DETECTOR

'.

7. 

Wait until the gateway is in connection mode (Once the connection mode has been established, you will 
see a notification on your screen). If this is not the case, click on '

CANCEL

' and '

TRY AGAIN

'. 

Please note: If no 

devices to be added are found, the connection mode will automatically be terminated after 2 minutes.

8. 

Press 3x briefly (less than 1 second) on the program switch of the sensor (C) to set up the connection with the 
gateway. Once the connection has been established, you will see a confirmation message on your screen. 

 

Please note: If no device is found within 30 seconds, press the programming button (A) again.

9. 

Once the smoke detector has been added, you will see a notification on your screen. 

10. 

If desired, change the name of the smoke detector.

Via the WEBSITE:
1. 

Go to home.fifthplay.com and log in.

2. 

Go to '

CONFIGURATION

'.

3. 

Go to '

DEVICES

'.

4. 

Click on '

ADD A DEVICE

'.

5. 

Click on '

ADD A SENSOR

'.

6. 

Select '

SMOKE DETECTOR

' and click on '

NEXT

'.

7. 

Wait until the gateway is in connection mode (Once the connection mode has been established, you will 
see a notification on your screen). If this is not the case, click on '

CANCEL

' and '

TRY AGAIN

'. 

Please note: If no 

devices to be added are found, the connection mode will automatically be terminated after 2 minutes.

8. 

Press 3x briefly (less than 1 second) on the program switch of the sensor (C) to set up the connection with the 
gateway. Once the connection has been established, you will see a confirmation message on your screen.

 

Please note: If no device is found within 30 seconds, press the programming button (A) again.

9. 

Once the smoke detector has been added, you will see a notification on your screen. 

10. 

If desired, change the name of the smoke detector. 
 
 

Summary of Contents for 98-401

Page 1: ...OR THE SMOKE DETECTORS 4 5 INSTALLATION AND ACTIVATION 5 6 ALARM SIGNALS AND VISUAL INDICATION 9 7 SERVICE LIFE AND FUNCTIONAL TEST 10 8 FEDERAL COMMUNICATIONS COMMISSION STATEMENT 10 9 LIMITED PRODUC...

Page 2: ...ork Each device driven by Z wave functions as a signal amplifier so that multiple devices ensure a greater number of transition routes which help to eliminate RF dead spots Z Wave devices with the Z W...

Page 3: ...CONTROL PARAMETERS Temperature 0 49 C Relative humidity 10 95 Action radius 30 m CURRENT STANDARD EN14604 2005 1172 CPR 150476 01 Z WAVE COMMAND CLASSES COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLA...

Page 4: ...n the ceiling is not possible mount the smoke detector on the wall at approximately 10 to 15 cm from the ceiling DON T Rooms in which strong water damp dust or smoke arise under normal conditions Clos...

Page 5: ...ctor by turning in a counter clockwise motion 2 Open the cover of the battery B place the battery and close the cover again 3 Place back the rear side of the smoke detector by turning in a clockwise m...

Page 6: ...nfirmation message on your screen Please note If no device is found within 30 seconds press the programming button A again 9 Once the smoke detector has been added you will see a notification on your...

Page 7: ...ation of the plugs and screws 3 Use a 5 mm drill and drill 2 holes on the marked locations 4 Place the plugs in the drill holes and secure the rear side A of the smoke detector in place by using the s...

Page 8: ...tion mode will automatically be terminated after 2 minutes 7 Press 3x briefly less than 1 second on the program switch of the sensor C to disconnect it from the gateway 8 Once the smoke detector has b...

Page 9: ...perly Red LED flashes once every 334 seconds LOW BATTERY VOLTAGE Red and orange LED flash continuously 1 beep every 43 seconds Push notification text message email DISMANTLING SECURITY the smoke detec...

Page 10: ...ike producers and importers you too play an important role in the promotion of sorting recycling and reuse of waste electrical and electronic equipment To finance the rubbish collection and waste trea...

Page 11: ...ur frequently asked questions page on cube fifthplay com FAQ or consult the user manuals on cube fifthplay com downloads 11 CONTACT Email hello fifthplay com Telephone 32 0 3 808 70 38 12 DISTRIBUTOR...

Reviews: