Technical specifications
Connector
230 V AC connection cable 4m with Schuko plug
Switching out-
put (optional)
Pairing of Wlan capable relays, such as .B. Shelly 1 possible
Pillar height
Reflector column: 119.8 cm / sensor column: 130 cm
Pillar width
9 cm without stand
Pillar depth
8,5 cm without stand
Stand
20 cm diameter
Weight
Reflector column: approx. 6.7 kg / sensor column: approx. 7.5 kg
IP protection
class
IP54. The columns are intended for indoor use. If the pillars are used outdoors, pro-
tection against precipitation must be provided by suitable methods. Drops on the
front sides of the pillars can lead to miscounts.
Maximum dis-
tance
between the
pillars
2 m
Minimum
detection
height of per-
sons
Persons from a height >1.20 m are detected.