System configuration
You can make the following settings for the system:
Current number of per-
sons
Correction of the current number of visitors.
Start value for number of
people after restart
Set as start value after a voltage reset. For example, you can Deduct your
staff from the maximum number of people.
Maximum number of per-
sons allowed
When the maximum number of people is reached, the traffic light switches to
red.
Difference to the max-
imum number of persons
for re-activation
Set this value if it is desired that after reaching the maximum a certain num-
ber of people must leave the area again before the traffic light switches back
to green
Number of persons less
than 0 allowed
If this option is active, the current person count is also decremented below 0.
Number of persons
greater 'Maximum num-
ber of persons' allowed
If this option is active, the current person count is also incremented by the
value 'Maximum number of persons' .
Acoustic alarm if the per-
missible number of per-
sons is exceeded
When this option is active, an audible warning is issued when an access is
crossed when the maximum number of people has already been reached
Error tolerance time
Adjustment alarm in
seconds
If the counting light barrier is interrupted, this time is maintained until an
adjustment alarm is triggered.
Fault tolerance time
Slave communication in
seconds
If a connected and active device does not log to the main column, this time
is waited until a communication alarm is triggered. This time is irrelevant if
you use the device as a single device.
Fault tolerance time for
external components in
seconds
If an event for an actuator cannot be sent for the set time, this is displayed in
the actuators overview.