3. Daily inspection of the safety device by authorized and designated personnel:
How to test your FLSC system properly:
1. The test must be performed every time the operating mode is changed.
2. Check the mechanical installation to ensure that all mounting screws are secure and that the FLSC
is properly aligned.
3. Check the FLSC for visible changes, such as damage, manipulation etc.
4. Switch on the machine / system.
5. Watch the LEDs on the FLSC (red, green, yellow).
6. If at least one LED does not shine constantly when the machine/system is switched on, it can be
assumed that there is a fault in the machine/system. In this case the machine must be shut down
immediately and checked by a specialist.
7. Deliberately obstruct the protective field while the machine is running in order to test the
effectiveness of the entire system. The LEDs must change from green to red and the hazardous
movement must come to an immediate standstill. Repeat this test at different points in the danger
area. If you discover any deviation from the proper function, the machine/system must be shut
down immediately and checked by a specialist.
8. For stationary applications, check that the danger area marked out on the floor matches the shape
of the protective field stored in the FLSC
and that any gaps are protected by additional safety
measures. In the case of mobile applications, check that the moving vehicle actually stops at the
field limits which are set in the FLSC and listed on the data plate in the vehicle or in the
configuration protocol. If you discover any deviation from the proper function, the machine / system
/ vehicle must be stopped immediately and checked by a specialist.