MOUNTING 

The following mounting options are available: 

 

Product comes with tabs for wall or surface mount.  These can be snapped off if not required. 

 

DIN Rail Mounting Bracket - included in the Accessory Kit or ordered separately (Part # FS-8915-35-QS)

 

 

 

3.1

 

Dimensions  

3.1.1

 

Dimension Drawing FS-QS-1X10-XXXX 

 

 

R1 Port 

R2 Port 

Tab 

Din Rail 

Summary of Contents for QuickServer 1011

Page 1: ...QuickServer Start up Guide FS QS 1010 1011 12X0 12X1 APPLICABILITY EFFECTIVITY Effective for all systems manufactured after August 2014 Kernel Version 6 15 Document Revision 0 ...

Page 2: ...D Device Instance 13 4 5 2 Using B0 B3 to set Baud Rate 14 4 5 3 DIP Switches S0 S3 14 5 Operation 15 5 1 Power up the device 15 5 2 Connect the PC to the QuickServer over the Ethernet port 15 5 3 Connecting to the QuickServer 16 5 3 1 Using the Toolbox application to Allocate the IP address 16 5 4 Set IP Address of the QuickServer 17 5 4 1 Using the Toolbox Application to set the IP address 17 5 ...

Page 3: ...twork Security 30 Appendix B Troubleshooting Tips 31 Appendix B 1 Communicating with the QuickServer over the Network 31 Appendix B 2 Technical support 31 Appendix B 3 Notes Regarding Subnets and Subnet Masks 31 Appendix C Limited 2 year Warranty 32 Appendix D Reference 33 Appendix D 1 LED Functions 33 Appendix D 2 FS QS 1010 XXXX LED s 34 Appendix D 3 FS QS 1011 XXXX LED s 35 Appendix D 4 QuickSe...

Page 4: ...dServer Driver Manuals o Support Utilities o Any additional folders related to special files configured for a specific QuickServer o Additional components as required See Driver Manual Supplement for details 2 1 BTL Mark BACnet Testing Laboratory The BTL Mark on the ProtoNode RER is a symbol that indicates to a consumer that a product has passed a series of rigorous tests conducted by an independe...

Page 5: ... Free 888 509 1970 email support fieldserver com 3 MOUNTING The following mounting options are available Product comes with tabs for wall or surface mount These can be snapped off if not required DIN Rail Mounting Bracket included in the Accessory Kit or ordered separately Part FS 8915 35 QS 3 1 Dimensions 3 1 1 Dimension Drawing FS QS 1X10 XXXX R1 Port R2 Port Tab Din Rail ...

Page 6: ...ieldServer Technologies 1991 Tarob Court Milpitas California 95035 USA Web www fieldserver com Tel 408 262 2299 Fax 408 262 2269 Toll Free 888 509 1970 email support fieldserver com 3 1 2 Dimension Drawing FS QS 1X11 XXXX LonWorks Port R2 Port ...

Page 7: ...Server Technologies 1991 Tarob Court Milpitas California 95035 USA Web www fieldserver com Tel 408 262 2299 Fax 408 262 2269 Toll Free 888 509 1970 email support fieldserver com 3 1 3 Dimension Drawing FS QS 12XX models with RS 422 R1 Port R2 Port ...

Page 8: ... Power jumper settings The QuickServer Carrier Board power jumper is set to position A by default but can be changed to position B for other power supply requirements A Position The Carrier makes use of a full wave rectifying bridge Can be used for 12 24 VAC input or 9 30 VDC input At 9 VDC this becomes marginal B Position The Carrier makes use of a half wave rectifying bridge Best position for Gr...

Page 9: ...dard RoHS Compliant FCC Part 15 Compliant DNP compliant OPC self tested to conformance CE Mark BTL Mark TUV approved to UL 916 Standard RoHS Compliant FCC Part 15 Compliant DNP compliant OPC self tested to conformance LonMark Certification SPID 80 00 95 46 00 84 04 01 Profiles 0000 Node object 1 0001 Open Loop Sensor Object 5 0003 Open Loop Actuator Object 5 Surge Suppression EN61000 4 2 ESD EN610...

Page 10: ...easonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in wh...

Page 11: ...nnector as shown The following Baud Rates are supported on the R2 Port 4800 9600 19200 38400 57600 115200 Refer to Appendix D 7 for the Dip Switch Settings for these Baud Rates For connection to RS 232 or RS 422 please refer to Appendix A 2 4 1 2 RS 485 Connection R1 Port Only on Non LonWorks QuickServers Connect to the 3 pin connector as shown The following Baud Rates are supported on the R1 Port...

Page 12: ...r LonWorks port insert a small screwdriver in the commissioning hole on the face of the QuickServer s enclosure to access the Service Pin See the instructions on the QuickServer as to which way to toggle the screwdriver during commissioning 4 3 QuickServer KNX FS QS 1011 XXXX or FS QS 12X1 XXX Connect the QuickServer to the KNX bus using the standard KNX twisted pair cable To commission the QuickS...

Page 13: ...urchased these DIP switches will have been configured at the factory If doing a self configuration each of these DIP switches will have to be configured Although it is technically possible to configure the DIP switches in a variety of ways it is recommended that the banks are configured as laid out in this manual It is necessary to restart the QuickServer in order for the DIP switch changes to tak...

Page 14: ...o set Baud Rate Refer to Appendix A 1 for configuration example The DIP switches B0 B3 can be set for standard Baud Rates between 110 and 115200 Baud Refer to Appendix D 6 for DIP switch settings 4 5 3 DIP Switches S0 S3 Refer to Appendix A 1 and Appendix A 1 3 for configuration example The S0 S3 DIP switch selection is read directly into a Data Array This Data_Array value can be used for customiz...

Page 15: ...ame GND terminal The QuickServer is factory set for 9 30VDC or 12 24VAC 5 2 Connect the PC to the QuickServer over the Ethernet port Disable any wireless Ethernet adapters on the PC Laptop Disable firewall and virus protection software Connect an Ethernet cable between the PC and QuickServer or connect the QuickServer and the PC to the Hub switch using a straight cat5 cable The Default IP Address ...

Page 16: ...62 2269 Toll Free 888 509 1970 email support fieldserver com 5 3 Connecting to the QuickServer 5 3 1 Using the Toolbox application to Allocate the IP address Install the Toolbox application from the USB drive or get it from our website http fieldserver com techsupport utility downloads php Use the Toolbox application to find the QuickServer and launch the Web GUI ...

Page 17: ...om 5 4 Set IP Address of the QuickServer 5 4 1 Using the Toolbox Application to set the IP address From the Toolbox main page click on the setup icon the gear picture Select Network Settings Modify the IP address N1 IP address field of the QuickServer Ethernet port If necessary change the Netmask N1 Netmask field Type in a new Subnet Mask If necessary change the IP Gateway Default Gateway field Ty...

Page 18: ...etwork hub or router 5 4 2 Using the Web GUI to set the IP address From the GUI main home page click on setup and then Network Settings to enter the Edit IP Address Settings menu Modify the IP address N1 IP address field of the QuickServer Ethernet port If necessary change the Netmask N1 Netmask field Type in a new Subnet Mask If necessary change the IP Gateway Default Gateway field Type in a new ...

Page 19: ... Start up Guide Page 19 of 43 FieldServer Technologies 1991 Tarob Court Milpitas California 95035 USA Web www fieldserver com Tel 408 262 2299 Fax 408 262 2269 Toll Free 888 509 1970 email support fieldserver com ...

Page 20: ...imited file called CONFIG CSV If a custom configuration was ordered the QuickServer will be programmed with the relevant device registers in the Config csv file for the first time start up If not the product is shipped with a sample config csv that shows an example of the drivers ordered In the main menu of the FS GUI screen go to Setup File Transfer Retrieve Click on config csv and open or save t...

Page 21: ... USA Web www fieldserver com Tel 408 262 2299 Fax 408 262 2269 Toll Free 888 509 1970 email support fieldserver com 6 3 Load the Updated Configuration file 6 3 1 Using the Toolbox application to load a configuration file From the Toolbox main page click on the setup icon the gear picture Select File Transfer ...

Page 22: ...2299 Fax 408 262 2269 Toll Free 888 509 1970 email support fieldserver com Browse and select the csv file open then click Update Config Once download is complete click the Restart Button or simply cycle power to the QuickServer to put the new file into operation Note that it is possible to do multiple downloads to the QuickServer before resetting it ...

Page 23: ...ldserver com 6 3 2 Using the Web GUI to load a configuration file In the main menu of the FS GUI screen go to Setup File Transfer Update Browse and select the csv file open then click Submit Once download is complete click the System Restart Button or simply cycle power to the QuickServer to put the new file into operation Note that it is possible to do multiple downloads to the QuickServer before...

Page 24: ...rd party device s and test the application From the main menu of FS GUI click on View Connections to see the number of messages on each protocol For troubleshooting assistance refer to Appendix B or any of the troubleshooting Appendices in the related Driver Supplements and Configuration Manual FieldServer Technologies also offers a Technical support page on the FieldServer website at www FieldSer...

Page 25: ...rays Data_Array_Name Data_Format Data_Array_Length Data_Array_Function Scan_Interval DA_A UINT16 1 Dip_Switches_A 2s DA_B BAUD 1 Dip_Switches_B 2s DA_S UINT16 1 Dip_Switches_S 2s Appendix A 1 1 Configure DIP switches A0 A7 To configure DIP switches A0 A7 to adjust the Device Id BACnet MAC address or both the dynamic parameters field needs to be added to the configuration file Dynamic_Parameters Fu...

Page 26: ... name for Config Table Up to 32 alphanumeric characters Table_Index_Value A unique value that will be used to identify which table entry needs to be used Table_String A String value representing the filename of the profile to be loaded for the corresponding Table_Index_Value 1 10 000 Restart_Method The specified config or profile is loaded on start up If the parameter is configured as On_Change th...

Page 27: ...lti drop multi master differential bus RS 422 is used for dedicated peer to peer high speed communication when low bus latency is required i e very few devices on the bus Its usage is very specific to client installations requirements Notes The RS 232 looks similar to the RS 485 but does not have the blue jumper The blue jumper is used to enable the termination resistor for the RX signals 120 ohms...

Page 28: ... 3 4 RX Differential RX inputs All signals must be connected to each other and same applies to signals no signals may be crossed Pin 5 SHD Shield connection must be connected on at least one side of the bus but not necessarily on both sides POWER connector Please note that AC voltage is not supported on the RS 422 Carrier and that DC voltage range is 20VDC to 28VDC Pin 1 24V DC power requires this...

Page 29: ...on such as temperature sensors shutters light switches actuators alarms etc This allows BMS systems to access a KNX network using direct read and write or with KNX configured groups This setup does not require the use of ETS4 to configure the QuickServer KNX gateway The KNX protocol is a connectionless protocol and therefore supports multiple clients and multiple servers The QuickServer is intende...

Page 30: ...sitive although the polarity of the M Bus connection is indicated on the device diagram should it be a requirement The M Bus devices communicating with the FieldServer must be configured according to the manufacturer s instructions e g Primary address and readout data The following Baud Rates are supported on the R2 Port 300 600 1200 2400 4800 9600 19200 38400 Appendix A 5 Enhanced Network Securit...

Page 31: ...hat the firewall is disabled Ensure that all other Ethernet cards active on the PC especially wireless adapters are disabled Refer to the FieldServer Troubleshooting Guide which can be found at www fieldserver com QS_Support for further information Appendix B 2 Technical support Before contacting Technical support to report an issue go to Start Programs FieldServer utilities Tools and run the FST_...

Page 32: ...l or which have been subjected to accident improper maintenance installation or application or on which original identification marks have been removed or altered This Limited Warranty also will not apply to interconnecting cables or wires consumables or to any damage resulting from battery leakage In all cases FieldServer Technology s responsibility and liability under this warranty shall be limi...

Page 33: ...Section 5 3 for more information once this LED starts flashing During the first 20 seconds the LED should be off ERR The ERR LED will go on solid 15 seconds after power up It will turn off after 5 seconds A steady red light will indicate there is a system error on the FieldServer If this occurs immediately report the related system error shown in the error screen of the FS GUI interface to FieldSe...

Page 34: ... on the FS QS 1010 XXXX If this occurs immediately report the related system error shown in the error screen of the FS_GUI interface to FieldServer Technologies for evaluation NODE OFF LINE The Node Offline LED will flash once on power up and flash once 15 seconds after power up If the Node Offline LED stays on solid a Node Offline condition has occurred RUN The RUN LED will start flashing 20 seco...

Page 35: ...tion error has occurred To establish the cause of the error go to the error screen of the RUI interface Config ERR LED3 The Config ERR LED will flash once on power up and flash once 15 seconds after power up A steady amber light will indicate a configuration error exists in the active configuration See the Error Screen in the Remote User Interface for a description of the configuration error Node ...

Page 36: ...ys N2 LonWorks 0097 JCI Metasys N2 BACnet MS TP 0309 JCI Metasys N2 BACnet IP 0122 Modbus RTU BACnet MS TP 0367 Modbus RTU BACnet IP 0104 Modbus RTU JCI Metasys N2 0038 Modbus RTU LonWorks 0085 Modbus TCP BACnet IP 0237 Modbus TCP LonWorks 0154 Modbus TCP BACnet MS TP 0419 Modbus TCP JCI Metasys N2 0117 SNMP BACnet IP 0333 SNMP LonWorks 0337 SNMP JCI Metasys N2 0150 Add BACnet MS TP LonWorks 0345 ...

Page 37: ...On On Off Off Off Off Off 8 Off Off Off On Off Off Off Off 9 On Off Off On Off Off Off Off 10 Off On Off On Off Off Off Off 11 On On Off On Off Off Off Off 12 Off Off On On Off Off Off Off 13 On Off On On Off Off Off Off 14 Off On On On Off Off Off Off 15 On On On On Off Off Off Off 16 Off Off Off Off On Off Off Off 17 On Off Off Off On Off Off Off 18 Off On Off Off On Off Off Off 19 On On Off Off...

Page 38: ...Off On Off On On Off Off 54 Off On On Off On On Off Off 55 On On On Off On On Off Off 56 Off Off Off On On On Off Off 57 On Off Off On On On Off Off 58 Off On Off On On On Off Off 59 On On Off On On On Off Off 60 Off Off On On On On Off Off 61 On Off On On On On Off Off 62 Off On On On On On Off Off 63 On On On On On On Off Off 64 Off Off Off Off Off Off On Off 65 On Off Off Off Off Off On Off 66 ...

Page 39: ...n Off Off Off On On Off 99 On On Off Off Off On On Off 100 Off Off On Off Off On On Off 101 On Off On Off Off On On Off 102 Off On On Off Off On On Off 103 On On On Off Off On On Off 104 Off Off Off On Off On On Off 105 On Off Off On Off On On Off 106 Off On Off On Off On On Off 107 On On Off On Off On On Off 108 Off Off On On Off On On Off 109 On Off On On Off On On Off 110 Off On On On Off On On...

Page 40: ...On On On On Off Off Off On 144 Off Off Off Off On Off Off On 145 On Off Off Off On Off Off On 146 Off On Off Off On Off Off On 147 On On Off Off On Off Off On 148 Off Off On Off On Off Off On 149 On Off On Off On Off Off On 150 Off On On Off On Off Off On 151 On On On Off On Off Off On 152 Off Off Off On On Off Off On 153 On Off Off On On Off Off On 154 Off On Off On On Off Off On 155 On On Off On...

Page 41: ...f On On On On Off On 189 On Off On On On On Off On 190 Off On On On On On Off On 191 On On On On On On Off On 192 Off Off Off Off Off Off On On 193 On Off Off Off Off Off On On 194 Off On Off Off Off Off On On 195 On On Off Off Off Off On On 196 Off Off On Off Off Off On On 197 On Off On Off Off Off On On 198 Off On On Off Off Off On On 199 On On On Off Off Off On On 200 Off Off Off On Off Off On ...

Page 42: ...ff On Off Off On On On 230 Off On On Off Off On On On 231 On On On Off Off On On On 232 Off Off Off On Off On On On 233 On Off Off On Off On On On 234 Off On Off On Off On On On 235 On On Off On Off On On On 236 Off Off On On Off On On On 237 On Off On On Off On On On 238 Off On On On Off On On On 239 On On On On Off On On On 240 Off Off Off Off On On On On 241 On Off Off Off On On On On 242 Off O...

Page 43: ...itch Settings Please refer to Section 4 1 1 and Section 4 1 2 for Baud Rate supporting Ports 4 Auto baud is only supported for BACnet MS TP Baud B0 B1 B2 B3 Auto4 Off Off Off Off 110 On Off Off Off 300 Off On Off Off 600 On On Off Off 1200 Off Off On Off 2400 On Off On Off 4800 Off On On Off 9600 On On On Off 19200 Off Off Off On 20833 On Off Off On 28800 Off On Off On 38400 On On Off On 57600 Off...

Page 44: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Sierra Monitor FS 8915 38 QS ...

Reviews: