Start-up guide 

Page 8 

FS-X20 Series FieldServer Start-up Guide (07-2005) 

3.  Operation 

3.1. Install and Run the Utility 

Software 

 
The FieldServer is shipped with a utility CD-
ROM  containing  all  the  utility  software  that 
needs to be installed. 
 
All  configuration  file  transfers  and  system 
diagnostics  are  executed  via  the  RUI  or 
“Remote  User  Interface”  which  is  installed 
with the utility software. 
 
Insert the supplied Utility CD into the PC and 
follow  the  installation  instructions  on  the 
screen.  
 
Once  installed,  the  FieldServer  Utilities  can 
be located in the Windows Start menu.  
 
Refer  to  the  FieldServer  Utilities  manual  for 
information  on  how  to  connect  to  the 
FieldServer via serial or Ethernet ports. 

 

3.2. Use PING to Identify the 

FieldServer on the Network 

 

Select 

Start|Programs|FieldServer 

Utilities,  browse  to  the  Ping  Utility  and 
select it 

 

The display should show 

FieldServer Name 
IP Number (192.168.2.X) 
FieldServer Version 

 

If  it  does  not  (even  after  repeated 
attempts)  then  either  the  network 
cabling  is  incorrect  or  the  computer 
network  card  is  faulty  or  incorrectly 
configured. 

 

Check  the  Ethernet  Link  OK  LED 
displayed on the FieldServer.  This LED 
will  be  lit  if  the  10/100BaseT  cable  is 
good. (Refer to Appendix B) 

 

Check the “Activity” LED on the Ethernet 
connection (see Figure 2-3), this should 
flash  at  least  once  every  2  seconds  if 
RUI  is  still  running,  and  perhaps  more 
often,  depending  on  network  traffic. 
(Refer to Appendix B) 

 

Check  that  the  IP  netmask  of  the  PC 
matches  the  FieldServer.    This  means 
the  first  three  sections  of  both  IP 
addresses match. 

 

Confirm  that  there  is  an  Ethernet 
adapter  installed  in  the  PC’s  Device 
Manager List, and that it is configured to 
run the TCP/IP protocol. 

 

If  using  Windows  XP,  ensure  that  the 
firewall is disabled. 

3.3. Connect using “Remote User 

Interface” (RUINET) 

Browse to the Remote User Interface icon in 
the Start menu directory and click on it - the 
RUI menu screen should appear. 
 
Refer  to  the  FieldServer  Utilities  manual  for 
further information. 
 

3.4. Use RUINET to change the 

FieldServer IP Address and 
Network 

Should  it  be  necessary  to  change  the  IP 
address of the FieldServer, this can be done 
via  the  “

I

”  screen  on  Ruinet.  Refer  to  the 

FieldServer Utilities manual for details. 

3.5. Upload the Default 

Configuration 

NOTE:    Refer  to  the  Configuration  Manual 
and  the  Driver  Manual(s)  provided  with  the 
FieldServer  for  further  information  on 
configuration files. 

 
The  configuration  of  the  FieldServer  is 
provided  to  the  FieldServer’s  operating 
system  via  a  comma-delimited  file  called 
“CONFIG.CSV”.    If  ordered  with  the 
FieldServer,  the  custom  configuration  is 
installed;  (Reference  documentation  FS-
8790-XX).  If  a  custom  configuration  is  not 
purchased,  a  template  config.csv  is  loaded 
on  the  FieldServer  to  facilitate  user 
configuration of the FieldServer. 
 
The  initial  default  configuration  software  will 
be  loaded  on  the  FieldServer.    In  the  main 
menu  of  the  Remote  User  Interface  screen, 
type  “

U

”  to  upload  the  configuration.    Then 

type  “

U

”  again.    The  Utility  will  fetch  the 

default  configuration  and  put  it  into  the 
Config  File  folder  which  is  located  in 
(Start|Programs|FieldServerUtilities|Configur
ation File folder). 

Summary of Contents for FS-X20 Series

Page 1: ...888 509 1970 Fax 408 262 2296 Email support fieldserver com Web Site www fieldserver com FS X20 Series FS X20 Start up Guide APPLICABILITY EFFECTIVITY This manual provides instructions for the following FieldServer products Description FS X20 Series FieldServer The instructions are effective for the above as of February 2005 Instruction Manual Part Number T17005 Rev D ...

Page 2: ... 5 3 OPERATION 8 3 1 Install and Run the Utility Software 8 3 2 Use PING to Identify the FieldServer on the Network 8 3 3 Connect using Remote User Interface RUINET 8 3 4 Use RUINET to change the FieldServer IP Address and Network 8 3 5 Upload the Default Configuration 8 3 6 Change the Configuration File to Meet the Application 9 3 7 Download the Updated Configuration File 9 3 8 Test and commissio...

Page 3: ...8915 13 RS 485 connector Part Number FS SPA59137 Set of four different connectors DB9M DB9F DB25M DB25F Part Number FS 8915 11 Power Supply Connector for power SPA59136 1 2 Start up Read this Start up Guide in conjunction with the Configuration Manual the 1 Note that a default configuration file has already been loaded onto the FieldServer Check the Driver Manual and the FieldServer Configuration ...

Page 4: ... the 9 24V 100mA required by the FieldServer during testing and start up Permanent 9 30V 100mA power will need to be provided for continuous operation The FS X20 Series FieldServer is shipped as either a FS X20XX 01 in which case the RS 232 port is activated or as a FS X20XX 02 in which case the RS 485 port is activated If using an RS 232 RJ45 Serial connection then use one of the RJ45 cables to c...

Page 5: ...62 2299 FS X20 OUTLINE DIMENSIONS FieldServer Tech n o lo g ies 408 262 2299 www fieldserver com FIELDSERVER BRIDGE FS B2010 01 Rx Tx Rx Tx Ethernet EIA232 USB EIA485 Power OK FieldBus Active FieldServer 3 82 4 08 1 70 0V INPUT 9 30Vdc 1A OR 24Vac 50 60HZ 1A Class 2 LPS Frame Ground Serial FieldServer Running Hot Standby Active Node Offline Configuration Error Comm Error System Error IP Request Fi...

Page 6: ...RJ45 02 RJ45 03 RJ45 04 RJ45 05 RJ45 06 RJ45 07 RJ45 08 DB9M 02 DB9M 08 DB9M 06 DB9M 05 DB9M 04 DB9M 07 DB9M 03 GREY BROWN YELLOW GREEN RED BLACK ORANGE BLUE WIRE LIST X20 FUNCTION FROM DEFAULT COLOR RX CTS DSR GND GND DTR RTS TX RJ45 01 RJ45 02 RJ45 03 RJ45 04 RJ45 05 RJ45 06 RJ45 07 RJ45 08 DB9F 03 DB9F 05 DB9F 02 WHITE BROWN YELLOW GREEN RED BLACK ORANGE BLUE WIRE LIST X20 FUNCTION FROM DEFAULT...

Page 7: ...ector C 11 Undefined 12 Secondary Rcvd Line Signal Detector C 13 Secondary Clear to Send C 14 Secondary Transmitted Data D 15 Transmitter Sig Element Timing T Timing 16 Secondary Received Data D 17 Receiver Sig Element Timing T 18 Undefined 19 Secondary Request to Send C 20 Data Terminal Ready C 21 Sig Quality Detector C 22 Ring Indicator C 23 Data Sig Rate Detector C 24 Transmitter Sig Element Ti...

Page 8: ...ge 7 FS X20 Series FieldServer Start up Guide 07 2005 FS 8917 16 FS X20 Serial G ORANGE WHITE RJ45 08 BROWN RJ45 01 BLUE WHITE RJ45 04 RJ45 Male Modular Jack Figure 2 8 RS 485 Connection pinouts on the serial RJ45 port ...

Page 9: ...ches the FieldServer This means the first three sections of both IP addresses match Confirm that there is an Ethernet adapter installed in the PC s Device Manager List and that it is configured to run the TCP IP protocol If using Windows XP ensure that the firewall is disabled 3 3 Connect using Remote User Interface RUINET Browse to the Remote User Interface icon in the Start menu directory and cl...

Page 10: ...d that the correct file names are specified Type D to send the file to the FieldServer The utility will display a menu showing download progress Note Wait until the utility indicates that download is complete before resetting the FieldServer or you could corrupt the FieldServer Once download is complete type Esc to get back to the main menu and use the option or simply cycle power to the FieldServ...

Page 11: ...tion or application or on which original identification marks have been removed or altered This Limited Warranty also will not apply to interconnecting cables or wires consumables or to any damage resulting from battery leakage In all cases FieldServer Technology s responsibility and liability under this warranty shall be limited to the cost of the equipment The purchaser must obtain shipping inst...

Page 12: ...t it may take a while from power up to booting up the FieldServer if the loaded configuration is particularly large The light indicates that the FieldServer firmware is running Configuration Error A steady amber light will indicate a configuration error exists in the active configuration See the Error Screen in the Remote User Interface for a description of the configuration error Comm Error A ste...

Page 13: ...Start up guide Page 12 FS X20 Series FieldServer Start up Guide 07 2005 THIS PAGE INTENTIONALLY LEFT BLANK ...

Reviews: